Clarke 7230294 Скачать руководство пользователя страница 5

5

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

5. ALWAYS use an approved cable extension suitable for the power rating of 

the pump (see specifications). The conductor size should also be at least 
the same size as that on the pump, or larger. When using a cable reel, 
always unwind the cable completely.

6. ALWAYS maintain the pump with care and keep it clean.

7. NEVER use for pumping flammable liquids or corrosive chemicals. These 

pumps are designed to pump water only.

8. NEVER abuse the electrical cable. Never use the cable for pulling or 

unplugging the pump. Damaged or tangled cables increase the risk of 
electric shock.

9. NEVER run the pump dry. Always ensure the pump is immersed in water 

before starting. Switch the pump off immediately the task is completed

10. NEVER pump water from a swimming pool when there is a person or animal 

still in the pool.

11. NEVER install the pump on sand, silt or mud which is likely to shift or 

collapse.

12. NEVER modify this pump in any way. Use it only for the purpose for which it 

is designed.

SERVICING & REPAIRS

1. ALWAYS have the pump serviced by your local CLARKE dealer, using only 

identical replacement parts. This will ensure the safety of the pump is 
maintained. The use of non standard parts could be hazardous.

2. NEVER attempt any repairs yourself unless qualified. If you have a problem 

with the pump contact your local CLARKE dealer.

3. ALWAYS disconnect the pump from the electrical supply before placing it 

into, or removing from the water, and before any cleaning or 
maintenance.

4. If the power cable becomes damaged, it must be replaced rather than 

repaired.

5. Your CLARKE water pump has been designed to give long and trouble free 

service. If, however, having followed the instructions in this booklet 
carefully, you encounter problems, take the unit to your local CLARKE 
dealer.

Содержание 7230294

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC08 22 ORIGINAL INSTRUCTIONS HIGH HEAD DRAINING PUMP MODEL NO CHHDP830 PART NO 7230294 ...

Страница 2: ...he head for the pump The pump is provided with a thermal overload cut out so that in the event that the pump becomes overheated due to becoming blocked etc it will shut off automatically When the blockage has been cleared the thermal cutout will cool down and re set and the pump can be re started Before attempting to use this product it is essential that you read this manual thoroughly and careful...

Страница 3: ... 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com OVERVIEW FEATURES 1 Water inlet screen 2 Power cable with plug 3 Water outlet elbow 4 Hose adaptor 5 Lifting handle Pump Performance curve ...

Страница 4: ...charge towards electrical wiring or equipment 4 ALWAYS store the pump out of reach of children and do not allow persons unfamiliar with these instructions to operate it 5 NEVER direct the discharge flow towards another person 6 ALWAYS thoroughly familiarise yourself with this pump its operation and follow all instructions in this manual 7 ALWAYS ensure that the pump is properly positioned where ne...

Страница 5: ...from a swimming pool when there is a person or animal still in the pool 11 NEVER install the pump on sand silt or mud which is likely to shift or collapse 12 NEVER modify this pump in any way Use it only for the purpose for which it is designed SERVICING REPAIRS 1 ALWAYS have the pump serviced by your local CLARKE dealer using only identical replacement parts This will ensure the safety of the pum...

Страница 6: ...this means that this product must not be disposed of with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a recognised disposal facility This product contains valuable raw materials Metal products should be takento your local civic amenity site for recycling of metal products Recycle unwanted materials instead of disp...

Страница 7: ... the power cable do not agree with the markings on the plug proceed as follows The BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal marked E or or coloured green AN APPROVED RESIDUAL CURRENT DEVICE RCD WHICH HAS A TRIPPING CURRENT OF LESS THAN ...

Страница 8: ...e operating area the pump should be placed vertically on house bricks or similar but ensure they are not likely to collapse Never position the pump on sand silt mud or ground which is likely to collapse 3 Route the hose as straight as possible Excessive bending of the hose could obstruct the flow of water reduce the pumping volume or clog the pump with mud thus disabling the pumps function If the ...

Страница 9: ...DRY 6 Disconnect the pump from the mains supply before placing it into or removing it from the water 7 NEVER insert your fingers into the pump whilst it is connected to the mains 8 DO NOT use the pump if the water is liable to freeze as this can cause damage to the pump Remove the pump from the water and store it in a frost free location OVERLOAD PROTECTION These pumps are fitted with automatic th...

Страница 10: ...ed for pumping swimming pool water or salt water likely to leave chemical residues it should be flushed through with clean water before storage 4 When the pump is not being used for extended periods clean and dry it thoroughly and store in indoors if the pump is left in water it should be run occasionally to prevent it from seizing up 5 If the pump shows signs of wear or damage contact your CLARKE...

Страница 11: ...connect from the mains supply and remove any objects that may be obstructing the impeller 6 If the pump still fails to start consult your CLARKE dealer PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the discharge tube is not clogged or obstructed 3 The head may be too great i e you are trying to lift the water too great a distance for the pump to cope with 4 Air bu...

Страница 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS ...

Страница 13: ...5 Washer 5 Bearing bracket 26 Screw 6 Seal cover 27 Screw 7 Impeller 28 Power cable 8 Impeller 29 Cable plate 9 Upper pump housing 30 Screw 10 Bottom pump housing 31 Pin 11 Base 32 Bolt 12 Strainer 33 Short screw 13 Capacitor 34 Long screw 14 Bearing 35 Washer 15 Bearing 36 Cap nut 16 Mechanical seal 37 Screw 17 Shaft sleeve 38 Washer 18 Oil seal 39 Bolt 19 O ring 40 Washer 20 O ring 41 Washer 21 ...

Страница 14: ...ate of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory ...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 16: ......

Отзывы: