Clarke 7160042 Скачать руководство пользователя страница 6

6

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

CONNECTION & OPERATION

1. Fit the carrying handle to the 

pump with the hex screw & washer 
provided.

2. If required, the pump can be 

installed in any horizontal 
mounting position and mounted to 
a flat surface using screws of 
adequate size (not supplied) 
through the mounting holes in the 
base.

• The pump should not be installed at more than 6m above the fuel 

supply.

3. Before connecting the pump, remove the travel plugs from the inlet/outlet 

ports.

4. If not already fitted, screw the inlet filter to the plastic suction hose.

5. Screw in either:

• A) the inlet and outlet hoses 

supplied or 

• B) the inlet adaptors for use with 

19 mm hoses

NOTE:

The transparent suction hose is 
connected to the side of the 
pump marked “IN” and the 
delivery hose to the side 
marked “OUT” on the pump 
casting.

• The hose and connections need to be completely air tight, 

otherwise air will be drawn in and reduce the flow. If required use 
PTFE tape.

6. Before connecting the delivery hose FOR THE FIRST TIME, partially fill the 

pump body with fuel to facilitate priming. Ensure the hoses and tank are 
free from contamination.

7. Insert the transparent suction hose & filter into the diesel fuel container.

WARNING: DO NOT USE WITH PETROL OR ANY OTHER HIGHLY FLAMMABLE 
LIQUID TO DUE TO THE POSSIBILITY OF SPARKING TAKING PLACE AND 
CAUSING FIRE.

Содержание 7160042

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0819 iSSUE 5 12 24V DIESEL FUEL TRANSFER PUMPS MODEL NO DFT12A DFT24A PART NO 7160042 7160047...

Страница 2: ...und you and you can look forward to your purchase giving you long and satisfactory service SPECIFICATIONS Please note that the details and specifications contained herein are correct at the time of go...

Страница 3: ...there is a danger of fire 2 Do not use to pump any liquid other than diesel paraffin and light fuel oil 3 Always ensure the ON OFF switch is in the OFF O position BEFORE connecting to the battery Thi...

Страница 4: ...is product must not be disposed of with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a recognised disposal facility...

Страница 5: ...PTION 1 Rubber Outlet Hose 3 4 male BSP end fittings 2 Transparent Inlet Hose 3 4 male end fittings 3 Dispensing Nozzle assembly 4 Carrying Handle c w fixing screw washer 5 12V or 24V Pump c w power c...

Страница 6: ...plastic suction hose 5 Screw in either A the inlet and outlet hoses supplied or B the inlet adaptors for use with 19 mm hoses NOTE The transparent suction hose is connected to the side of the pump mar...

Страница 7: ...ve clamp first 12 Ensure the clamps cannot be disturbed easily and that the setup is protected from passers by 13 Set the switch to ON I Ensure the transparent inlet suction hose and inlet filter clea...

Страница 8: ...slowly when starting Low supply voltage Check condition of battery Lack of flow delivery Low level in the storage tank Foot filter blocked Pump is positioned too high above the storage tank By pass va...

Страница 9: ...parts as most plastics are susceptible to damage from various types of commercial solvents Keep the filter on the inlet hose free of accumulated dirt Store the pump in dry conditions protected from th...

Страница 10: ...V 24V 3 O Ring 20 Bearing 4 Rotor 21 Circlip 5 Blade 22 Seal 6 Pump Body 23 By pass Valve 7 By pass Spring 24 Screw M5 x 10 8 Handle 25 Base 9 Fuse 15A 25A 26 Key 10 Fuse Holder 27 Relay SPST 11 Singl...