background image

OPERATION & MAINTENANCE

INSTRUCTIONS

ORIGINAL INSTRUCTIONS                                              GC0819 iSSUE 5

12&24V DIESEL FUEL TRANSFER PUMPS

MODEL NO: 

DFT12A & DFT24A

PART NO: 7160042 & 7160047

Содержание 7160042

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0819 iSSUE 5 12 24V DIESEL FUEL TRANSFER PUMPS MODEL NO DFT12A DFT24A PART NO 7160042 7160047...

Страница 2: ...und you and you can look forward to your purchase giving you long and satisfactory service SPECIFICATIONS Please note that the details and specifications contained herein are correct at the time of go...

Страница 3: ...there is a danger of fire 2 Do not use to pump any liquid other than diesel paraffin and light fuel oil 3 Always ensure the ON OFF switch is in the OFF O position BEFORE connecting to the battery Thi...

Страница 4: ...is product must not be disposed of with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a recognised disposal facility...

Страница 5: ...PTION 1 Rubber Outlet Hose 3 4 male BSP end fittings 2 Transparent Inlet Hose 3 4 male end fittings 3 Dispensing Nozzle assembly 4 Carrying Handle c w fixing screw washer 5 12V or 24V Pump c w power c...

Страница 6: ...plastic suction hose 5 Screw in either A the inlet and outlet hoses supplied or B the inlet adaptors for use with 19 mm hoses NOTE The transparent suction hose is connected to the side of the pump mar...

Страница 7: ...ve clamp first 12 Ensure the clamps cannot be disturbed easily and that the setup is protected from passers by 13 Set the switch to ON I Ensure the transparent inlet suction hose and inlet filter clea...

Страница 8: ...slowly when starting Low supply voltage Check condition of battery Lack of flow delivery Low level in the storage tank Foot filter blocked Pump is positioned too high above the storage tank By pass va...

Страница 9: ...parts as most plastics are susceptible to damage from various types of commercial solvents Keep the filter on the inlet hose free of accumulated dirt Store the pump in dry conditions protected from th...

Страница 10: ...V 24V 3 O Ring 20 Bearing 4 Rotor 21 Circlip 5 Blade 22 Seal 6 Pump Body 23 By pass Valve 7 By pass Spring 24 Screw M5 x 10 8 Handle 25 Base 9 Fuse 15A 25A 26 Key 10 Fuse Holder 27 Relay SPST 11 Singl...

Страница 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 12: ......

Отзывы: