SPECIFICATIONS

WIRING DIAGRAM

Model

XR80

XR110

XR160

XR210

Burn Rate: (Btu/hr.)

70,000

100,000 160,000

210,000

Fuel consumption: 

1.9 L/hr.

2.8 L/hr.

4.16 L/hr.

3.91L/hr.

Approx Running Time:

11.9 hr

11.4 hr

12.7

13.5

Electrical input:

230V   ~50Hz

Power

165 W

204 W

279 W

307W

Max.Outlet Temp:

1300°F (704°C)

Fuel Tank Capacity: 

22.7 L

32 L

53 L

53 L

Ignition system:

Electric Ignition

Primary Safety Control:

Flame failure device

Weight (kg)

17.6

19.85

26.1

26.2

Dimensions (DxWxH) mm

830 x 410 x 648

905 x 413 x 700

1045 x 528 x 692

1030 x 523 x 692

Содержание 6931004

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0618 ISS 5 ORIGINAL INSTRUCTIONS DIESEL PARAFFIN HEATERS MODEL NO XR80 XR110 XR160 XR210 PART NO 6931004 6931006 6931008 6931012 ...

Страница 2: ...ION AND OPERATING PARAMETERS This is a multi fuel Diesel or Paraffin forced air heater It s intended use is for drying and the warming of commercial industrial buildings where adequate ventilation is provided It must be operated as prescribed in the operating manual Is not intended to be used for domestic use or for the heating of habitable areas Is not intended to be used to reach and maintain a ...

Страница 3: ...e to comply with the precautions and instructions provided with this heater can result in death serious bodily injury and property loss or damage from the hazards of fire explosion burns asphyxiation carbon monoxide poisoning and or electric shock 2 Only persons who understand and follow the instructions should use or service this heater 3 When used the heater should rest on a suitable insulating ...

Страница 4: ...CO can build up in a confined spaces and failure to provide adequate ventilation can be fatal The early symptoms of asphyxiation caused by inadequate ventilation are Be sure to follow all warnings in this manual WE RECOMMEND THE USE OF A CARBON MONOXIDE DETECTOR BYSTANDERS When the heater is to be operated in the presence of other people the user is responsible for informing those present of the s...

Страница 5: ...ck The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green We strongly recommend that this machine is connected to the mains supply through a Residual Current Device RCD If you are not sure consult a qualified electrician DO NOT try to do any repairs WARNING READ THESE ELEC...

Страница 6: ...not directly exposed to rain or water spray 7 Never use in living spaces and or where children may be present 8 Operate on a stable level surface 9 Do not use with ductwork Do not restrict air inlet or exit 10 Do not move or service the heater while hot or in operation 11 Use only in accordance with local regulations and relevant building codes 12 The heater is not to be used by children or person...

Страница 7: ...onto each end 3 Place a wheel on to each end 4 Place a flat washer onto each end 5 Secure everything in place by inserting a split pin into the small hole at the end of the axle 6 Place the handle into position and secure using four 50 mm bolts and nuts provided 2 each side 7 Place the wheel assembly into position and secure using four 30 mm bolts and nuts provided 2 each side ...

Страница 8: ...se this is available from your local Clarke service department part number GF0K070000 3 Fill the fuel tank with clean diesel or paraffin In cold weather condensation may develop in the tank if the tank is empty and it is recommended that a tablespoon of de icer be added for each gallon of fuel in the tank When filling the heater make sure that the heater is level and do not overfill Use a funnel o...

Страница 9: ...tting 5 Start heater by setting the power switch to the ON position The switch illuminates in the ON position 6 Adjust thermostat to desired setting NOTE Heater will cycle on off as heat is required HEATER SHUT DOWN 1 Set the power switch to the OFF position 2 For extended shutdown unplug the heater from the mains supply BEFORE STORAGE Clean the heater as described in the MAINTENANCE section We re...

Страница 10: ...is no smoke or soot internal or external to the heater There are no unplanned or unexplained shut downs of the heater REMOVE DUST Clean the heater twice a season more often under dusty conditions 1 Remove accumulated dust from the transformer burner motor and fan blades with compressed air 2 Wipe clean with a clean dry cloth FUEL TANK EVERY 500 HOURS Clean twice a season during frequently used per...

Страница 11: ...eater to ignite This heater should never be operated without the filters in place If required clean the filters as follows ACCESSING THE FILTERS 1 Make sure that the plug is removed from the power supply before carrying out any maintenance 2 Remove the six screws shown and remove the top cover of the heater NOTE There may be eight screws on the larger models 3 Lift out the rear guard 4 Remove the ...

Страница 12: ...solid object to remove contaminates NOTE Compressed air or liquids should not be used to clean this filter NOTE If the filter appears damaged or extremely dirty replace it with a new filter of the same type must be obtained and fitted this is available from your local Clarke service department part number GF50K100401 8 Reinstall clean filter in to the filter body in the same position as it was whe...

Страница 13: ...Heater fails to start 1 Check fuel level 2 Check the mains plug is correctly fitted and that the fuse inside it has not blown 3 Return to Clarke service department for repair 3 Flashes High limit switch failure unit has overheated Make sure heater is cooled down 1 Make sure that the power switch is set to the OFF position 2 Wait 5 minutes 3 Start heater by setting the power switch to the ON positi...

Страница 14: ... consumption 1 9 L hr 2 8 L hr 4 16 L hr 3 91L hr Approx Running Time 11 9 hr 11 4 hr 12 7 13 5 Electrical input 230V 50Hz Power 165 W 204 W 279 W 307W Max Outlet Temp 1300 F 704 C Fuel Tank Capacity 22 7 L 32 L 53 L 53 L Ignition system Electric Ignition Primary Safety Control Flame failure device Weight kg 17 6 19 85 26 1 26 2 Dimensions DxWxH mm 830 x 410 x 648 905 x 413 x 700 1045 x 528 x 692 ...