AIR INTAKE FILTER CLEANING
6. To clean the air intake filter.
• Remove and wash the filter
element with a mild detergent.
• Dry thoroughly and refit.
• Do not oil the filter element. If
your heater is used where there
is considerable dust or dirt.
• Clean as often as necessary (at
least approximately every 500
hrs.).
NOTE:
If the filter is damaged or extremely dirty, a replacement filter of the
same type must be fitted, this is available from your local Clarke service
department part number GF50K100406.
AIR OUTPUT FILTER CLEANING
7. To clean the air output filter (Annually or as required)
• Remove the air output filter and tap the contaminated side gently
on a solid object to remove contaminates.
NOTE:
Compressed air or liquids should not be used to clean this filter.
NOTE:
If the filter appears damaged or extremely dirty, replace it with a new
filter of the same type must be obtained and fitted this is available from
your local Clarke service department part number GF50K100401.
8. Reinstall clean filter in to the filter body in the same position as it was when
removed.
9. Replace the filter cover and secure using the screws removed in step 4.
NOTE:
When replacing the filter cover, make sure that the gasket is firmly in
place and the screws in the filter cover are tight to prevent air leaks. if
the gasket is damaged a replacement must be obtained and fitted
this is available from your local Clarke service department part number
GF50K100407.
10. Refit the rear guard and replace the top cover.
11. Make sure all screws are replaced before use.
STORAGE
Store the heater in a dry location free from fumes or dust.
Содержание 6931004