12
Occasionally it may be necessary to manually clean the fan, to do this
proceed as follows.
1. Switch OFF and isolate from the main electrical supply by removing the
plug from the socket, ensuring it is not possible to be plugged back in
accidentally.
2. Remove the 12 screws securing the inlet cover and remove the cover to
expose the fan.
3. Clean the fan using a brush, cleaning cloth, vacuum cleaner and/or low
pressure compressed air.
CAUTION: BEWARE OF SHARP EDGES. IF ANY SERVICING (OTHER THAN
THE ABOVE CLEANING) BECOMES NECESSARY, IT SHOULD BE CARRIED
OUT BY AN AUTHORISED SERVICE CENTRE.
TROUBLESHOOTING
Problem
Probable Cause Suggested Remedy
Motor will not run.
Excessive sawdust in the
air.
Excessive impeller noise.
Motor fails to develop
full power.
1. Defective cable, switch
and / or motor.
1. Consult your nearest Clarke
dealer.
1. Loose connectors.
2. Filter/dust bag worn or
damaged.
1. Tighten connectors.
2. Replace bag.
1. Impeller dirty. (dust buildup)
2. Loose or impeller rubbing.
1. Switch OFF and isolate from
mains. Clean impeller.
2. Consult your nearest Clarke
dealer.
Excessive noise.
1. Defective motor.
2. Loose fan.
1. Circuit overloaded.
2. Extension lead undersize,
too long or not fully
unwound.
1. Use on separate circuit.
2. Change extension lead.
Motor starts slowly fails to
reach full speed.
1. Low voltage.
2. Windings burned out or
open circuit.
1. Request voltage check
from power company.
2. Have motor repaired or
replaced.
Motor does not start
when ON switch is
pressed.
1. Switch contacts burnt.
2. Start capacitor faulty.
1. Have switch replaced.
2. Have capacitor replaced.
1. Consult your nearest Clarke
dealer.
Содержание 6471150
Страница 13: ...13 DUST COLLECTOR PARTS DIAGRAM ...
Страница 16: ......