GENERAL SAFETY RULES

1. Always ensure when jump-starting that there is air circulating around the 

machine.

2. Never allow the negative and positive leads on this unit, to touch each 

other or to touch the same metal object.

3. Although the jump-start is water resistant and may be used outdoors, DO 

NOT leave it exposed to the elements. Avoid direct sunlight, direct heat, 
rain/moisture etc.

4. The JS4000 jump-start is designed for use with 12V systems.

5. Do not operate the jump-start if any of the cables are damaged. Consult 

your CLARKE dealer for repair or replacement of the parts.

6. Do not operate the jump-start if the case is damaged. Consult your 

CLARKE dealer or a qualified person for inspection and repair.

7. Ensure the vehicle battery posts and battery clamps are perfectly clean 

before use.

8. When connecting the jump-start leads to a battery, ensure the ON/OFF 

switch is OFF, and ALWAYS connect the RED, (po’) output conductor 
to the UNEARTHED (+) battery terminal FIRST, then connect the BLACK, 
(negative) conductor to a suitable earthing point on the chassis, well away 
from any fuel lines.

9. To prevent the battery overheating and consequent damage, do not 

exceed our recommendations for the duration of jump starting.

10. Always wear suitable protective clothing and eye protection when working 

with lead-acid batteries.

11. The jump-start is NOT designed to be used as a replacement for a vehicle 

battery.

12. DO NOT attempt to BOOST CHARGE the jump-start's sealed battery.

13. Never allow the battery to become completely discharged.

14. Never jump-start the engine whilst the jump-start is being charged.

15. Never allow the cables to become wrapped around the operator or any 

other person.

16. Never attempt any repairs yourself. If you have a problem with the jump-

start contact your local CLARKE dealer.

17. Always keep your body and clothing dry. Never work in damp area without 

adequate insulation against electric shock.

Содержание 6240030

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0819 JUMPSTART MODEL NO JS4000 PART NO 6240030...

Страница 2: ...eep these instructions in a safe place for future reference SPECIFICATIONS Please note that the details and specifications contained herein are correct at the time of going to print However CLARKE Int...

Страница 3: ...cting the jump start leads to a battery ensure the ON OFF switch is OFF and ALWAYS connect the RED positive output conductor to the UNEARTHED battery terminal FIRST then connect the BLACK negative con...

Страница 4: ...ery and environmentally sound disposal of the WEEE In effect this means that this product must not be disposed of with general household waste It must be disposed of according to the laws governing Wa...

Страница 5: ...BLUE coloured cable to the plug terminal marked a letter N If the battery charger for this appliance is fitted with a plug which is moulded on to the electric cable i e non rewireable please note 1 Th...

Страница 6: ...tly fitted for jump starting wrong polarity 1 Positive Battery Connecting Lead to connect to positive battery terminal 7 Voltage Meter to indicate the volt age level of the units battery 2 Lamp to pro...

Страница 7: ...plug provided NOTE Using a 12V vehicle supply the battery will not charge to maximum but only to approx 50 of its capacity NOTE A 5 amp fuse is fitted into the cigarette lighter plug adaptor accessed...

Страница 8: ...o the cigar lighter socket on the vehicle and start the engine The red LED on the jump start will indicate that charging is in progress 2 Continue to charge until the Internal Battery Status gauge reg...

Страница 9: ...lines 3 Connect the black negative clamp to the negative battery terminal or to a suitable earthing point on the vehicle chassis ensuring the connections are firm and secure If the polarity is incorre...

Страница 10: ...ve clamp from the battery terminal and restore to its storage position 8 After use always recharge the jump start If the battery is allowed to remain in a discharged state its life may be shortened 9...

Страница 11: ...or to other DC electrical equipment WARNING Be Aware that a fully charged 12V battery can have an output of approx 13 5V Consult the appliance handbook to ensure it is safe to operate from a 12V batte...

Страница 12: ...arefully you encounter problems take the unit to your local CLARKE dealer REPLACING THE BATTERY 1 Unscrew and remove the self tapping screws securing the back cover Lift off the cover to expose the ba...

Страница 13: ...minal IMPORTANT The old moulded plug MUST be thrown away DO NOT RE USE GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep y...

Страница 14: ...e available as follows No Description Part Number 1 Positive Battery Connection Lead HT400001 2 Lamp Assembly HT400002 3 Lamp Bezel with Lens HT400003 4 230 Volt Charger assembly HT400017 5 Cigar Ligh...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: