13
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
THE CONTROL PANEL
1. Wire speed control knob.
As a general rule, a higher current requires a
higher wire speed.
2. Current setting switches MIN-MAX & 1-2.
Used together, these two switches
provide 4 increasing power levels as follows:
• MIN-1
• MIN-2
• MAX-1
• MAX-2
3. Power ON/OFF switch.
When the power is ON the green switch will be
illuminated. When the welder is no longer required, the Power On/Off switch
should be switched to the OFF position and the plug should be disconnected
from the mains supply.
4. Thermal overload light.
If the duty cycle is exceeded as a result of welding
for too long with a high current, the overload light will illuminate and the
welder will turn off. When the welder has cooled down (approx. 5 to 10
minutes), the power will be restored and welding can recommence.