Clarke 6012785 Скачать руководство пользователя страница 8

8

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

• When reversing the motor, ensure that the motor has stopped fully 

before doing so.

• For some applications of small motors or motors of unusual magnetic 

characteristics, it may be necessary to provide a pilot motor to obtain a 
balance of phases. Generally the pilot motor should be a 2 pole (2800 
rpm) motor and as a general guide should be at least twice as big as 
the motor to be driven.

If necessary, consult a qualified technician.

PARTS LIST & DIAGRAM

No

Description

Suppliers No

1

Frame

EM21690441

2

Green Pilot Light Switch 16A-250V

EM22200039

3

Circuit Breaker 10A

EM22210005

4

Ammeter 8A F516

EM 22600045

5

Front Panel

EM 33710372

6

Handle

EM 21600045

7

Contactor 220V 10A

EM 22225006

8

Cover Panel

EM 33705460

9

Relay LY2 24VDC

EM 22225318

10

Socket For LY2 Relay PTF 80A

EM 22225319

11

Orange Pilot Lamp 220V

EM 22610013

12

Cable Clamp For Cable Diam.6+ Screw

EM 04600233

13

Input Cable 3x1,5 M2,5 W/UK Plug +Fuse 13A

EM 20220068

14

Double Pole Black Switch

EM 22200043

15

CEE 16A 380V 3PH Panel Earth

EM22105067

16

Capacitor 4.7mf-63V 5x11 P-2

EM26000005

16

W10 Rectifier

EM 26014005

17

6k8 Ohm 50W Armoured Resistance

EM26031001

18

Auto transformer 

EM 44145002

19

Capacitor Support

EM 33640256

Содержание 6012785

Страница 1: ...USER INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1220 PHASE CONVERTER MODEL NO PC20 PART NO 6012785...

Страница 2: ...and that of others around you and is also to help you achieve long and trouble free service from your new product SPECIFICATIONS GUARANTEE This CLARKE product is guaranteed against faulty manufacture...

Страница 3: ...the responsibility of the user to resolve the situation In some cases it could involve constructing an electromagnetic screen enclosing the power source and the work complete with associated input fi...

Страница 4: ...Once the location has been established the installation may be carried out as follows ELECTRICAL CONNECTION Check details on converter rating plate are compatible with the electric supply and the mach...

Страница 5: ...E or Earth symbol or coloured GREEN or GREEN YELLOW Connect BROWN wire to plug terminal marked letter L or coloured RED Connect BLUE wire to plug terminal marked letter N or coloured BLACK CONNECTING...

Страница 6: ...OFF the converter and connect the plug from the motor to the output socket E 3 Using the three switches G set the output so that it is equivalent to the HP of the motor to be driven This value should...

Страница 7: ...the Converter which is greater than the rated power of the motor being driven Ensure also the wiring to the motor is of sufficient size so as not to incur losses If the machine which is to be fed from...

Страница 8: ...escription Suppliers No 1 Frame EM21690441 2 Green Pilot Light Switch 16A 250V EM22200039 3 Circuit Breaker 10A EM22210005 4 Ammeter 8A F516 EM 22600045 5 Front Panel EM 33710372 6 Handle EM 21600045...

Страница 9: ...com or Service clarkeinternational com PARTS LIST DIAGRAM 20 Lower Panel EM33700265 21 Capacitor MKM 5MF 450V 35x48 EM22315025 21 Capacitor MKM 8MF 450V 30x 78 EM22315026 21 Capacitor MKM 16MF 450V 4...

Страница 10: ...10 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com WIRING DIAGRAM...

Страница 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 12: ......

Отзывы: