![Clarke 6012785 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/clarke/6012785/6012785_user-instructions_2615160004.webp)
4
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
INSTALLATION
We would recommend that the installation of this equipment is carried out by
a qualified electrician, who has a full understanding of industrial switching
applications.
It is the users responsibility to provide adequate protection for the intended
motor and to ensure that the supply and cabling is of sufficient capacity to
enable the motor to start without causing undue supply disturbances due to a
voltage drop.
Before installing this equipment, careful consideration must be given to the
location in which it is to be used, also what machinery it is intended to run,
such as drills, lathes, milling machines, circular saws etc.
Once the location has been established, the installation may be carried out as
follows.
ELECTRICAL CONNECTION
Check details on converter rating plate are compatible with the electric
supply and the machine to be driven. (machine details should be found on
the motor data plate).
NOTE:
The converter will only supply a 3 phase, 3 line load as standard, if a
neutral is required. Contact your nearest dealer or Clarke Service for
advice.
NOTES:
• Cable sizes above are the minimum sizes for up to 20 metres. For cables
over this length refer to the current IEE regulations.
• Model PC20 is provided with 2M (minimum) of 3-core cable fitted with a
13amp plug, for use with a standard, domestic 13 amp supply.
IMPORTANT: The wires in the mains lead are coloured in accordance with
the following code:
Green & Yellow ...........Earth
Blue ...........Neutral
Brown ...........Live
WARNING: THESE CONVERTERS ARE NOT SUITABLE FOR USE WITH CAR
HOISTS, COMPRESSORS & VACUUM PUMPS DUE TO THEIR HIGH START UP
LOADS.
Содержание 6012785
Страница 1: ...USER INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1220 PHASE CONVERTER MODEL NO PC20 PART NO 6012785...