Clarke 6012785 Скачать руководство пользователя страница 6

6

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

OPERATION

1. Before inserting the output plug, 

switch all three switches (G) to 
OFF. Then switch the converter 
ON, using the ON/OFF switch (A) 
on the front panel.

In this condition the lamp (B) and 
the rocker switch A will illuminate.

Check to ensure the ammeter (C) is 
set to zero. If necessary, adjust 
using the small adjustment screw 
located at the bottom centre of 
the ammeter so that it reads zero.

2. Switch OFF the converter and 

connect the plug from the 
motor to the output socket (E).

3. Using the three switches (G), set 

the output so that it is equivalent 
to the HP of the motor to be 
driven. This value should be found on the motor data plate.

The chart below shows the switch settings for the required outputs.

4. With the switches set, and the output plugged in, switch ON the converter 

and proceed to start the motor/machine. Note that indicator lamp (F) will 
illuminate when the switches (G) are set.

DO NOT ADJUST THE SWITCHES (G) WHEN THE PHASE CONVERTER IS SWITCHED 
ON.

Model PC20

Motor HP

SW 1 

0.5HP

SW 2 

0.5HP

SW3 

1|HP

0.5

ON

OFF

OFF

0.5

OFF

ON

OFF

1

ON

ON

OFF

1

OFF

OFF

ON

1.5

ON

OFF

ON

1.5

OFF

ON

ON

2

ON

ON

ON

Содержание 6012785

Страница 1: ...USER INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1220 PHASE CONVERTER MODEL NO PC20 PART NO 6012785...

Страница 2: ...and that of others around you and is also to help you achieve long and trouble free service from your new product SPECIFICATIONS GUARANTEE This CLARKE product is guaranteed against faulty manufacture...

Страница 3: ...the responsibility of the user to resolve the situation In some cases it could involve constructing an electromagnetic screen enclosing the power source and the work complete with associated input fi...

Страница 4: ...Once the location has been established the installation may be carried out as follows ELECTRICAL CONNECTION Check details on converter rating plate are compatible with the electric supply and the mach...

Страница 5: ...E or Earth symbol or coloured GREEN or GREEN YELLOW Connect BROWN wire to plug terminal marked letter L or coloured RED Connect BLUE wire to plug terminal marked letter N or coloured BLACK CONNECTING...

Страница 6: ...OFF the converter and connect the plug from the motor to the output socket E 3 Using the three switches G set the output so that it is equivalent to the HP of the motor to be driven This value should...

Страница 7: ...the Converter which is greater than the rated power of the motor being driven Ensure also the wiring to the motor is of sufficient size so as not to incur losses If the machine which is to be fed from...

Страница 8: ...escription Suppliers No 1 Frame EM21690441 2 Green Pilot Light Switch 16A 250V EM22200039 3 Circuit Breaker 10A EM22210005 4 Ammeter 8A F516 EM 22600045 5 Front Panel EM 33710372 6 Handle EM 21600045...

Страница 9: ...com or Service clarkeinternational com PARTS LIST DIAGRAM 20 Lower Panel EM33700265 21 Capacitor MKM 5MF 450V 35x48 EM22315025 21 Capacitor MKM 8MF 450V 30x 78 EM22315026 21 Capacitor MKM 16MF 450V 4...

Страница 10: ...10 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com WIRING DIAGRAM...

Страница 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 12: ......

Отзывы: