ELECTRICAL CONNECTIONS

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply 
through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.

If the plug has to be changed because it is not suitable for your socket, or 
because of damage, it must be removed and a replacement fitted, following 
the wiring instructions shown below. The old plug must be discarded safely, as 
insertion into a power socket could cause an electrical hazard.

If the colours of the wires in the power cable do not agree with the markings 
on the plug.

• The BLUE wire must be 

connected to the 
terminal which is 
marked N or coloured 
black.

• The  BROWN  wire  must 

be connected to the 
terminal which is 
marked L or coloured 
red.

• The YELLOW AND 

GREEN wire must be 
connected to the 
terminal which is marked E or 

 or coloured green.

We strongly recommend that this machine is connected to the mains supply 
through a Residual Current Device (RCD)

If you are not sure, consult a qualified electrician. DO NOT try to do any 
repairs.

WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS 
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS 
SUPPLY.

WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE 
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL      BROWN = LIVE     YELLOW AND GREEN = EARTH

Plug must be BS1363/A approved.

Always fit 

Ensure that the outer sheath of 

Neutral

(Blue)

Live

(Brown)

Earth

(Green and 

a 13 Amp 

the cable is firmly held by the clamp

fuse.

Yellow)

Содержание 6012149

Страница 1: ...instructions before using the machine WARNING A suitable welding headshield must be worn during use OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS DL0821 ISS 3 ARC TIG MMA WELDER MODEL NO AT...

Страница 2: ...uct is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have...

Страница 3: ...of the cables for signs of damage Remove the plug from the mains socket when not in use do not leave the machine unattended Ensure the earth clamp is secured to bare metal adjacent to the weld seam a...

Страница 4: ...clothing The use of neck protection may be necessary against reflected radiation Arc welding machines generate a magnetic field which is detrimental to pacemakers Consult your doctor before going nea...

Страница 5: ...with any of the panels removed NEVER attempt any electrical or mechanical repair unless your are a qualified technician If you have a problem with the machine contact your local CLARKE dealer NEVER u...

Страница 6: ...E In effect this means that this product must not be disposed of with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a...

Страница 7: ...connected to the terminal which is marked N or coloured black The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the term...

Страница 8: ...for the power rating of this tool see specifications the conductor size should also be at least the same size as that on the machine or larger When using a cable reel always unwind the cable complete...

Страница 9: ...nnect the welding leads as follows Welding rod holder lead to the ve terminal Work clamp lead to the ve terminal 2 Select the appropriate welding rod and insert it into the welding rod holder The size...

Страница 10: ...ectrode on the workpiece As soon as the arc is primed withdraw the electrode from the workpiece to leave a tiny gap of around 1 5mm 1 16 The current will flow across the gap with a crackling noise and...

Страница 11: ...o the leading edge of the weld pool to fill the joint This process is ideally suited for welding thin metals such as car body panels pressure vessels heat exchangers pipes etc where accuracy and a hig...

Страница 12: ...e regulator on to the gas bottle tightly and attach the gas hose to the inlet connector securely with a hose clip 4 Turn the pressure regulator knob to set a pressure of approx 2 5kg cm2 35 lbf in2 5...

Страница 13: ...u finish welding NOTE To avoid a visible strike mark on the surface of the workpiece it is advisable to strike the arc in the joint where the mark will be concealed by the weld Thin sheet and stainles...

Страница 14: ...od Dia mm Welding Electrode Dia mm Gas Flow ltr min Mild Steel 20 30 1 0 1 1 6 4 5 60 80 2 1 2 1 6 1 6 4 5 80 110 3 1 6 2 0 1 6 2 4 4 5 100 130 3 5 2 0 2 4 2 4 5 6 130 140 4 2 4 2 4 6 7 140 150 4 5 2...

Страница 15: ...heavy deposit which overlaps at the sides It is wasteful both in terms of time and electrode use ELECTRODE MOVED TOO QUICKLY This causes poor penetration with a stringy and incomplete weld deposit Sla...

Страница 16: ...rest CLARKE dealer Inverter printed circuit is defective Contact your nearest CLARKE dealer Wrong output current Current selector control is defective Contact your nearest CLARKE dealer Low power supp...

Страница 17: ...dition and not cracked 3 Always avoid getting particles of metal inside the machine since they could cause short circuits High Sprays Electrode is too inclined Make appropriate corrections Profile def...

Страница 18: ...Voltage Symbol 3 Serial Batch Number 14 Energy Supply Symbol 4 Welding Power Source 15 Rated Supply Voltage 5 British Standards applied 16 Rated Maximum Supply Current 6 Welding Process Symbol 17 Maxi...

Страница 19: ...any time without prior notice ACCESSORIES The following are some of the accessories available from your CLARKE dealer Please quote the part numbers shown below AT165 Unpacked Weight kg 7 85 Dimensions...

Страница 20: ...20 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com EXPLODED DIAGRAM PARTS LIST AT165...

Страница 21: ...very diode 4 Switch 20 Control PCB 5 Cable Gland 21 Main PCB 6 Fan Grille 22 Rubber Foot 7 Power Cable 23 Base Frame 8 Bridge Heatsink 24 Front Plastic Panel 9 IGBT Radiator 25 Quick connector ASM 10...

Страница 22: ...22 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY UKCA...

Страница 23: ...23 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY CE...

Страница 24: ...24 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com...

Отзывы: