8
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
CONNECTING THE AIRLINE
1. Remove the protective plug from
the air inlet port and connect a
suitable hose as shown.
2. Connect the other end of the hose
to the compressed air supply.
3. Turn on the air supply and check
for air leaks. Rectify any found
before proceeding.
• PTFE tape may be useful for
sealing threaded connections.
4. If required, connect an in-line mini oiler to the tool.
• A mini oiler helps to prolong the life of the air tool.
5. If a mini-oiler is not being used, run a few drops of oil through the tool
before use. It can be entered through the airline inlet or via the hose at the
nearest connection to the air supply.
6. A gauze filter is fitted within the air inlet. Ensure this filter is always in place
and is kept clean. An airline is connected to the adapter, preferably via a
quick release coupling (not supplied).
7. Ensure the trigger is NOT depressed when connecting the airline.
• Your air tool is now ready for use
• You can fit a whip hose with a quick fit coupling if required
(available from your Clarke dealer.)
OPERATION
OPERATING THE SANDER
1. Ensure your fingers are clear of the sanding belt.
2. To begin work, rest the belt on the workpiece and gently start the sander.
3. Squeeze the throttle lever against the body of the tool to start the sander.
WARNING: COMPRESSED AIR CAN BE DANGEROUS. ENSURE THAT YOU
ARE FAMILIAR WITH ALL PRECAUTIONS RELATING TO THE USE OF AIR
COMPRESSORS AND A COMPRESSED AIR SUPPLY.
Содержание 3120179