4

GENERAL MACHINE USE AND CARE

1. Prior to use, all operators should become familiar with the instructions in this 

booklet especially the ON/OFF switch for emergency stopping.

2.

ALWAYS

 maintain the compressor with care and keep it clean for best / 

safest performance.

3.

NEVER 

use this compressor if any part is damaged. Have it inspected and 

repaired by your dealer.

4.

NEVER 

attempt to modify the air compressor, tank, fittings or attachments in 

any way. Doing so will invalidate the guarantee and could result in 
personal injury.

5.

NEVER 

abuse the power cable.

 

Never pull on the cable when removing the 

plug from the socket, or lift the compressor by the power cable.

6.

ONLY

 use extension leads that are of an appropriate power rating and 

suitable for the work environment. Extension leads must have an earth 
connection. Inspect the extension lead regularly and replace if damaged.

7.

ONLY USE RECOMMENDED PARTS: 

To avoid the risk of bursting, only hoses 

with a rated pressure of 10 bar, or more should be used. Never attempt to 
repair damaged hoses.

8.

NEVER 

abuse the compressor by standing on it.

AIRLINE HOSES

1.

ALWAYS

 ensure that equipment or power tools used in conjunction with the 

compressor have a safe working pressure exceeding that of the machine.

2.

ALWAYS

 keep the air hose away from any attached power tools and 

ensure that the operator is not restricted by the length of the hose.

3.

ALWAYS

 take care when a long air hose is required in the work area as it 

presents a trip hazard. Coil the hose away as soon as the job is finished.

4.

ALWAYS

 avoid kinking or trapping the air hose. Always replace faulty hoses 

and never attempt a repair if a leak is detected.

5.

NEVER

 abuse hoses or connectors. NEVER carry an air tool by the hose, or 

yank it to disconnect from the air supply. Keep hoses away from heat, oil 
and sharp edges. Check hoses for leaks or worn condition before use and 
ensure that all connections are secure.

6.

ALWAYS

 ensure that the air supply is turned off at the machine outlet and 

any air pressure vented from within the compressor and any attached 
equipment when disconnecting air hoses or other equipment.

Содержание 2320865

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1220 rev 11 SILENT AIR COMPRESSOR MODEL NO SHHHAIR 30 9 PART NO 2320865...

Страница 2: ...faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered...

Страница 3: ...elf against electric shock Never operate the compressor in wet or damp locations 4 NEVER over reach Keep your proper footing and balance at all times to enable better control of the compressor in unex...

Страница 4: ...ressure of 10 bar or more should be used Never attempt to repair damaged hoses 8 NEVER abuse the compressor by standing on it AIRLINE HOSES 1 ALWAYS ensure that equipment or power tools used in conjun...

Страница 5: ...he compressor repaired by a qualified service engineer Do not use the compressor if the On Off switch does not operate correctly 7 KEEP THE MOTOR AIR VENTS CLEAR Keep the motor vents clear and free fr...

Страница 6: ...e colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The Blue wire must be connected to the terminal marked N...

Страница 7: ...Do not allow it to run if it is standing on an incline Check also that the mains voltage corresponds with that shown on the data label on the side of the compressor The ON OFF switch is in the OFF pos...

Страница 8: ...without any oil inside 1 Remove the oil cap from the top of the oil filler tube 2 Pour the oil into the oil filler tube using the funnel on the bottle then replace the oil cap Only use Clarke synthet...

Страница 9: ...r outlet tap the motor will start automatically once the cut in pressure is reached 2 Allow the compressor to run for 10 15 seconds with the air outlet tap A open This will distribute the lubricating...

Страница 10: ...set open the air outlet tap 7 If the machine pumps continuously without cutting out then the compressor is too small for the application tool being used and damage may result Consult your Clarke deal...

Страница 11: ...Take the compressor to the sink and place the free end of the small hose in the sink 4 Tilt the compressor forward slightly and slowly open the vent valve 5 When the reservoir has been drained re tig...

Страница 12: ...possible that you are trying to use more air than the compressor is capable of delivering Renew oil filler air Filter plug Air leaking from the pressure switch valve when the compressor is not runnin...

Страница 13: ...d ensuring the sealing ring is in perfect condition and is located correctly Daily Monthly Yearly Check the oil level See Adding Oil on page 6 X Drain the water collected in the air outlet filter See...

Страница 14: ...y cloth and reassemble the valve taking care to place the internal rubber disc 2 as shown 4 Fasten the valve to the connection and join the flexible hose If the leakage persists the whole valve must b...

Страница 15: ...ns that this product must not be disposed of with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a recognised disposal...

Страница 16: ...16 COMPONENT DIAGRAMS PARTS LIST...

Страница 17: ...17 PUMP ELECTRICAL DIAGRAM...

Страница 18: ...M5X 6 C0051 Rylsan Hose 4 6 C0077 Swivel Connector M1 4 C0082 Pressure 1 WAY C0083 Connection M 1 4 L 80 C0089 Nipple 1 4 L 95 C0091 Electric Cable MM 500 C0348 T Connection F F F 1 4 C0133 Electric...

Страница 19: ...19 DECLARATION OF CONFORMITY...

Страница 20: ......

Отзывы: