15
ASSEMBLY & INSTALLATION
A. LOOSE COMPONENTS
MIG’s, 90EN, 100EN & 105EN
Lay the welder gently on its side and attach the four feet using the screws and flat
washers provided.
MIG 151EN only
Insert the axle through the holes in the rear base of the machine, then attach the
wheels, securing them by pushing the star locking washers provided, on to the
axle, using a piece of tube or an old socket, ensuring the centre tines of the washer
face outwards.
Lay the machine gently on its side and attach the foot to the front base using the
screw and washer provided.
Attach the handle to the top of the machine by slotting it into place and securing with
the screws provided. Slide the handle extension into the handle and secure with the
screw provided.
The gas bottle is secured to the machine using the large worm drive fastening band
which is threaded through the opening provided on the rear panel of the machine.
on welding shield maintenance, given on page 23. When replacing the glass
panels, use ONLY those parts supplied by Clarke International. The dark panel is a
certified, specific optical class, and should not be exchanged for any other type.
The clear glass panel should be replaced when it becomes badly pitted.
WARNING:
NEVER look at an electric arc without eye protection as this can injure the
eyes permanently. ALWAYS use a protection mask or welding helmet.
B. THE WELDING SHIELD
To assemble the welding shield, (Fig.2),
insert the clear glass panel first, followed
by the dark glass panel into the recess in
the shield, i.e. the clear glass MUST be on
the outside of the shield. Securing them
with the plastic screws provided.
Slot the two pieces together as shown, and
enter the threaded end of the handle
through the holes provided. Thread on the
plastic nut and tighten.
It is important to pay attention to the notes
Fig.2
Содержание 100EN
Страница 29: ...WIRING DIAGRAMS MIG 100EN 105EN 30...
Страница 30: ...PARTS DIAGRAM MIG 100EN 105EN 34...