Nitrogen Generators
Nitro35 Nitro70
9
4.
Installation
4.1.
Installation preparation guide
4.1.1.
Moisture and particulate
In order to avoid damages to the electronic components, we recommend to in-
stall the generator in a area where the relative moisture and the dust concentra-
tion are limited.
Moreover, the generator must be protected from dripping, rain and wind.
4.1.2.
Temperature
Environmental temperature of the area of the installation must be between 5°c
and 40°c.
Please avoid proximity to heat sources. Please avoid the direct exposition to sun
beams.
4.2.
Generator positioning
4.2.1.
Handling
The packed generator can be handled using an adequate instrumentation, such
as a transpallet or a fork lift. Once unpacked, it can be moved by his own wheels.
m
If suddenly moved the generator could fall and generate damage to
things or persons.
e
The generator must be always kept in vertical position since it has not been de-
signed to be layed down.
4.2.2.
Unpacking
The generator is shipped on a dedicated pallet.
Please remove packing paying attention not to damage the panels of the gene-
rator.
When possible, please keep the original packing to guarantee an adequate pro-
tection of the generator in case of future handling.