36
LCD Screen Operation - Section B
12:12 PM
ADVANCED SETTINGS 1
Periodic Pulse Reduced Cavitation Mode
Hot setpoint must be < 98°C to disable
Pre-pulse Reduced Cavitation Mode
Adds slight delay to boiling dispense
Power Pulsing Mode
Hot setpoint must be < 98.5°C to disable
A lower fan speed can reduce
noise.
Increasing the speed can improve
the cooling performance.
Levels: 75% / 100% / Auto (de-
fault).
These settings serve to reduce
cavitation in the hot water pump.
V. Quiet Mode
VI. Advanced Settings I
LIGHT SENSOR
12:12 PM
CALIBRATION
This will calibrate the light sensor which will allow the
system to go to sleep when it is dark.
Before we start, the room should be in a typical
ambient lit environment.
Remove any object away from the tap.
Follow the instructions on the
display. Before each calibration,
make sure that the ambient light
corresponds to the typical light-
ing conditions at the installation
site.
IV. Light Sensor (Classic- & Classic Plus only)
Remove any refl ective or shadowing objects from around the fi x-
ture.
Periodic Pulse reduced Cavitation Mode
The pump is briefl y moved every 5 minutes. This prevents the for-
mation of air bubbles in the pump and ensures a steady fl ow of hot
water.
Pre-Pulse reduced Cavitation Mode
Before each hot water tap, the pump is moved briefl y to fl ush out
bubbles. There is a delay of 150 milliseconds before the water is
dispensed.
Power Pulsing Mode
To ensure that the hot water is kept as close as possible to the set-
point, the tolerances for temperature fl uctuations are reduced.