9
Instructions for user - DSX - 801049 - November 2018 v1.00 Art.no:
9120-34371
6. Operation
Info menu
2
1
4
3
5
Press
≥ 3 sec
Menu item order of “Info menu“:
POWER LIMIT
FX CHANNEL
TEMPERATURE PROTECTION
OPERATING COST PER HOUR
WORKING TIME
STANDBY TIME
LIFETIME COUNTER
FLOW
TEMP IN
TEMP OUT
POWER
CONTROL VALUE
DIAGNOSTICS
SIGNAL
SOFTWARE VERSION
Info menu
The Info menu offers a variety of display values, that provide information on vari-
ous parameters.
Press the info key for at least 3 seconds to call up the Info menu, the display con-
firms by “Info”.
Using the arrow keys and you can switch over to the individual display informa-
tion. With info key you will get back to the standard display.
Individual display values as follows:
Power limit
Informs about the current maximum power rating (kW) of the appliance.
Temperature protection
Information, if temperature protection is activated or deactivated.
Operating cost per hour
Indication about the current energy consumption given in Euro per hour.
Working time
Indication of total operating time of the heating given in seconds / minutes / days /
years.
Standby time
Indication of the operating time since latest connection of the appliance to the supply
voltage given in seconds / minutes / days / years.
Lifetime counter
Indication of the total operating time of the appliance given in seconds / minutes /
days / years.
Flow
Indication of current flow rate given in l/min.
Temp in
Indication of inlet temperature (°C).
Temp out
Indication of outlet temperature (°C).
Power
Indication of current power consumption (kW).
Control value
Indication of calibration value of the control system.
Diagnostics
Indication of the last ten diagnostic messages.
Signal
Indication of the current I
2
C-connection quality in %.
Software version
Information about installed software version.