Instructions for user - DSX - 801049 - November 2018 v1.00 Art.no:

 9120-34371

3. Technical data

Model

DSX

Part no.

27940 - 50 °C model

27941 - 60 °C model

Energy efficiency class

A *

)

Rated capacity / rated current

18 kW..27 kW (26 A..39 A)

Chosen capacity / current

18 kW 

(26 A)

21 kW 

(30 A)

24 kW 

(35 A)

27 kW 

(39 A)

18 kW 

(26 A)

21 kW 

(30 A)

24 kW 

(35 A)

27 kW 

(39 A)

Electrical connection

3~ / PE 380..415 V AC

3~ / PE 

400 V AC

3~ / PE 380..415 V AC

3~ / PE 

400 V AC

Min. required cable size 

1)

see note 1)

Hot water (l/min) 

2)

max. at ∆t = 28 K
max. at ∆t = 38 K

9.2
6.8

10.7

7.9

12.3

9.0

13.8
10.2

9.2
6.8

10.7

7.9

12.3

9.0

13.8
10.2

Rated volume

0.4 l

Rated pressure

1.0 MPa (10 bar)

Connecting type

pressure-resistant / pressureless

Heating system

Bare wire heating system IES®

@ 15 °C:
Required spec. water resistance Spec. 
electrical conductivity

≥ 1,100 Ωcm

≤ 90 mS/m

Inlet temperature

≤ 70 °C

Flow rate to switch on – max. flow rate

2.5 l/min – automatic 

3)

Pressure loss

0.2 bar at 2.5 l/min     1.3 bar at 9.0 l/min

Temperature range

20 – 50 °C

20 – 60 °C

Water connection

G ½“

Weight (when filled with water)

4.2 kg

VDE class of protection

I

Noise level test certificate

PA-IX 6822/I

Type of protection / safety

IP25

*) The declaration complies with the EU regulation No 812/2013
1) The cross sectional area of the connection cable must be in accordance with the power rating of the appliance and the specific requirements of AS/NZS 3000
2) Mixed water
3) Electronically controlled depending on the desired temperature and cold water temperature

Содержание Zip DSX 27940

Страница 1: ...Hot Water Electronically controlled instantaneous water heater DSX 27940 50 C and 27941 60 C models Instructions for the user For 50 C models the appliance delivers water not exceeding 50 C in accord...

Страница 2: ...view 4 3 Technical data 5 4 Dimensions 5 5 Description of the appliance 6 6 Operation 6 Temperature setting 6 Programme keys 6 Info menu 7 Setup menu 8 Energy Efficiency Monitor 10 6 Operation 11 7 Ma...

Страница 3: ...se a feeling of burning Please note that the fittings and taps may be very hot when the appliance has been in use for some time The appliance is only suitable for domestic use and similar applications...

Страница 4: ...ensor 8 99385 Non return valve 9 DSX hood 10 Bottom part 11 Wall bracket 12 DSX connecting pipe 13 99386 PCB cover 2 1 Pos Part No Description 14 Control panel support 15 Connecting terminal 16 99387...

Страница 5: ...ype pressure resistant pressureless Heating system Bare wire heating system IES 15 C Required spec water resistance Spec electrical conductivity 1 100 cm 90mS m Inlet temperature 70 C Flow rate to swi...

Страница 6: ...4 Dimensions 231 231 170 363 466 56 100 97 Dimensions in mm...

Страница 7: ...nlet tempera ture and the flow rate thus reaching the set temperature exactly to the degree and keeping it constant in case of pressure fluctua tions The required outlet temperature can be entered wit...

Страница 8: ...with arrow key the display shows and the appliance switches off the heating function Programme keys The four programme keys at the device allow to quickly select the preset temperature The factory set...

Страница 9: ...e appliance Temperature protection Information if temperature protection is activated or deactivated Operating cost per hour Indication about the current energy consumption given in Euro per hour Work...

Страница 10: ...h info key you will get back to the standard display Individual parameter as follows Language Operating language can be selected Setting options 1 German 0 English Tone Activation and deactivation of...

Страница 11: ...2 same as 1 additionally the setup menu cannot be opened 3 same as 2 additionally nominal value memory handwash shower bathtub kitchen not changeable 4 same as 3 additionally nominal value not change...

Страница 12: ...clock was enabled in the Setup menu it is only shown in normal display mode Note The menu items Power Flow Temp In Temp Out and Costs per hour are explained in the chapter Info Menu Energy last tappin...

Страница 13: ...e water already heated would cool down again and valuable energy would be wasted Moreover the cold water added in the tap is not covered by the control range of the electronic cir cuitry with the resu...

Страница 14: ...ently running dry Nevertheless the appliance must be vented before using it for the first time Each time the appliance is emptied e g after work on the plumbing system if there is a risk of frost or f...

Страница 15: ...tal display does not light up Master fuse tripped Renew or activate fuse Safety pressure cut out tripped Contact customer service Water stays cold digital display does light up Safety thermal cut out...

Страница 16: ...been modified and may not be true representations of the finished goods Quick reference guide Set temperature 1 1 C 1 C Convenience zone 35 0 42 0 C 1 0 5 C 0 5 C Store temperature 2 Press 3 sec 3 1 I...

Отзывы: