CLAGE
Type
SX 50 (E)
SX 80 (E)
SX 100 (E)
SX 120 (E)
Energy-efficiency class
C *
)
Rating power
1)
W
750...4500
1000...6000
2000...6000
Rating volume
l
50
80
100
120
Weight (empty)
kg
21
26
33
42
Installation
vertical
Model
see data plate
Max. working pressure MPa / bar
0,6 / 6
Qelec
kWh
6,422
6,405
12,557
12,541
V40
2)
l
90
144
180
216
Heating time to
approx. 85 °C with
cold water inlet
temperature 15 °C
1 kW
h
4,3
6,8
8,5
10,3
2 kW
h
2,1
3,4
4,3
5,1
3 kW
h
1,4
2,3
2,8
3,4
4 kW
h
1,1
1,7
2,1
2,6
6 kW
h
0,7
1,1
1,4
1,7
Protection class
IP24D
*) The declaration complies with the EU regulation No 812/2013. The product data sheet is attached at the end of this document.
1) The power rating varies depending on connection and operation mode
2) Volume of mixed water at 40 °C with storage content temperature of 60 °C and inlet temperature of 15 °C
Typ : SX XX (E) EU
Nr.: XXXXXX-XXXXXX
Nenninhalt: XX l
CLAGE GmbH
Pirolweg 1-5
21337 Lüneburg
(Deutschland)
Nenndruck: 0.6 MPa (6 bar)
3N AC 380-415V
50-60 Hz
Nr XXXXXXX XX XXXXX
XXXXXXX
2N AC 380-415V
1/6;2/6;1/4;2/4 kW
AC 220-240V
1/6;2/6 kW
IP24D
DIN
AGI
1/4;2/4 kW
Behälter: St em
19
Basically Legionella can come up again when the water temperature drops below 55 °C.
Caution: Water temperature in the tank can cause severe burns instantly. Children, disabled and elderly are at
highest risk of being scalded. Feel water before bathing or showering.
3. Technical Data
For the technical characteristics of the appliance, please refer to the information provided on the data plate (label locat-
ed near the water inlet and outlet pipes).
Содержание SX 100
Страница 27: ...CLAGE I 1 2 3 4 2 1 C A 5 6 7 8 9 B 1 bei MOD 50 80 100 1 for MOD 50 80 100 2 bei MOD 120 2 for MOD 120...
Страница 28: ...SX50 SX80 SX100 SX120 II 3 Dimensionen Dimensions 4A...
Страница 29: ...CLAGE III 4B 5 6 MOD 120 MOD 50 80 100 C...
Страница 30: ...SX50 SX80 SX100 SX120 IV 7 8 10 11 9...
Страница 31: ...CLAGE V 12 1 Anschlussarten Einkreis Boiler Betrieb Single power and boiler connection...
Страница 32: ...SX50 SX80 SX100 SX120 VI 12 2 Anschlussarten Zweikreis Double power connection...