SX 50 / SX 80 / SX 100 / SX 120
Power Switch “S1”
Mode of Operation
Double power switch positions 5 / 6 / 7
(see page IV)
Single power switch positions 1/ 2 / 3 / 4
(see page V)
Boiler mode switch positions 8 / 9 / 0
(see page V)
5. Initial operation
22
Operating modes
Single Power Operation
Connection without off-peak contact.
The appliance heats with the adjusted performance. The ‘FAST’ button is only used for the reset and diagnose func-
tions.
Connection with off-peak contact.
If the ‘FAST’ button (fig. 1, ref. B) is activated, the device heats once to the configured temperature. All LED ther-
mal capacity indicators (fig. 1, ref. 4,5 and 6) light up as soon as the configured temperature has been reached.
Afterwards, the device turns itself off automatically.
Double Power Operation
Connection without off-peak contact.
The reservoir heats with the configured basic performance. The “FAST function” activates a heating cycle at higher
installed power in order to accelerate the heating-up procedure. To start this function, press the ‘FAST’ button. The LED
‘FAST’ (fig. 1, ref. 3) lights up. The function turns itself off automatically, as the soon as the configured temperature has
been reached. The LED ‘FAST’ turns off.
Connection with off-peak contact.
During off-peak time the device heats with the configured basic performance.
The “FAST function” activates a heating cycle at higher power in order to accelerate the heating-up procedure. To start
this function, press the ‘FAST’ button. The LED ‘FAST’ lights up. The function turns itself off again automatically as soon
as the configured temperature has been reached. The LED ‘FAST’ turns off. The rest of the time, the device does not
heat. If the ‘FAST’ button is activated, the device heats once to the configured temperature. All 3 LED thermal capacity
indicators light up as soon as the configured temperature has been reached. Afterwards, the device turns itself off
automatically.
Boiler Mode
Connection without off-peak contact.
The device does not heat by default. If the ‘FAST’ button is activated, the device heats once to the configured temper-
ature. All 3 LED thermal capacity indicators (fig. 1, ref. 4,5 and 6) light up as soon as the configured temperature has
been reached. Afterwards, the device turns itself off automatically. Each further heating process must be started by
pushing the button ‘FAST’.
Power switch
Set the power switch “S1” to the correct operating mode on the electronic board. Set the desired load according to the
connection examples.
The power switch is manufacturer set in position 5 for 50 (E), 80 (E) and 100 (E) models and in position 6 for 120 (E).
Содержание SX 100
Страница 27: ...CLAGE I 1 2 3 4 2 1 C A 5 6 7 8 9 B 1 bei MOD 50 80 100 1 for MOD 50 80 100 2 bei MOD 120 2 for MOD 120...
Страница 28: ...SX50 SX80 SX100 SX120 II 3 Dimensionen Dimensions 4A...
Страница 29: ...CLAGE III 4B 5 6 MOD 120 MOD 50 80 100 C...
Страница 30: ...SX50 SX80 SX100 SX120 IV 7 8 10 11 9...
Страница 31: ...CLAGE V 12 1 Anschlussarten Einkreis Boiler Betrieb Single power and boiler connection...
Страница 32: ...SX50 SX80 SX100 SX120 VI 12 2 Anschlussarten Zweikreis Double power connection...