Installation site
• Appliance must only be installed in frost-free rooms. Never expose appliance to
frost.
• The Appliance must be wall mounted and has to be installed with water connectors
downward.
• The appliance complies with protect-ion type IP 25 and may therefore be installed in
protection zone 1 according to VDE 0100 part 701.
• In order to avoid thermal losses, the distance between the instantaneous water
heater and the tapping point should be as small as possible.
• The appliance must be accessible for maintenance work.
• Copper or steel connecting pipes may be used. Plastic pipes may only be used if
they conform to DIN 16893, Series 2. The hot water pipes must be thermally insu-
lated.
• The specific resistance of the water must be at least 1300 Ω cm at 15 °C. The specific
resistance can be asked for with your water distribution company.
5. Installation
The following regulations must be observed:
• VDE 0100
• EN 806
• Installation must comply with all statutory regulations, as well as those of the
local electricity and water supply companies.
• The rating plate and technical specifications
• Only intact and appropriate tools must be used
For installations under difficult conditions, these mounting accessories are available:
Mounting accessories
Mounting kit RDX
(Art. no. 34100)
The instant water heater can be installed by means of this mounting kit in the below
situations. The power supply cable is coming out of the wall at any place from behind
the unit, but the wall has unusual surface conditions, making it difficult for installing
the water heater. The power supply cable is coming from elsewhere and has to be con-
nected to the back of the unit.
Extension kit VDX
(Art. no. 34120) – RDX is necessary! –
The instant water heater can be installed by means of this extension kit if the water
pipes are coming displaced or exchanged out of the wall or if they are coming edge-
wise on the wall to the unit. The power supply could come out of the wall at any place
under the unit or the wiring could be installed surface-mounted.
Extension kit UDX
(Art. no. 34110) – RDX is necessary! –
The instant water heater can be installed by means of this extension kit if the water-
connections are expiring above the unit. The power supply could come out of the wall
at any place under the unit or the wiring could be installed surface-mounted.