6. Direct connection

Note: Fasten the screw nuts with caution, to avoid damage to the valves or the 
piping system. 

For direct connection, the two ½ inch screw-in nipples and the ½ inch seals must be 
screwed into the ½ inch union nuts of the hot-water and cold-water connectors. The 
two ½ inch caps of the side outlets of the hot-water and cold-water connectors must 
be removed and screwed onto the open end of the screw-in nipples. The hot-water and 
cold-water connectors must then be screwed into the 

3

/

8

 inch union nut of the appli-

ance and delivery pipe, together with the 

3

/

8

 inch seals. 

For direct connection, it is advisable to mount the appliance at a distance as illustrated 
alongside, using the spacer sleeves supplied. It should therefore be noted that the two 
fixing holes near the lower pipe connections are also used. 
The flared end of the pipes must be screwed into the ½ inch side outlets of the hot-
water and cold-water connectors with ½ inch union nuts and ½ inch seals. The holes 
required for the pipes must then be broken out of the housing with the aid of a blunt 
implement.

In case of direct connection please note: Put the strainer into the cold water con-
nection!

Содержание DEX 12

Страница 1: ...Montageanleitung f r den Fachhandwerker Installing instructions for the professional 09 18 de 3 en 17 E Komfortdurchlauferhitzer DEX12 E convenience instant water heater DEX12...

Страница 2: ......

Страница 3: ...wendbaren Materialien und Kompo nenten hergestellt Beachten Sie bei einer Entsorgung dass elektrische Ger te am Ende ihrer Lebensdauer vom Hausm ll getrennt entsorgt werden m ssen Bringen Sie dieses G...

Страница 4: ...ter Anschlussklemme Einlaufrohr Kaltwasseranschlussst ck Spritzwasserschutzt lle Durchf hrungst lle G Zoll Einschraubnippel Feinfilter Durchflussmengenregler 5l min Rahmen DEX Ger tehaube R ckflussver...

Страница 5: ...drucklos Heizsystem Blankdraht Heizsystem IES Einsatzbereich bei 15 C spez Wasserwiderstand 1300 cm spez elektr Leitf higkeit 77mS m Zulauftemperatur 25 C Einschalt max Durchfluss 2 5 5 0l min 2 Druc...

Страница 6: ...r rtlichen Energie und Wasser versorgungs unternehmen Technische Daten und Angaben auf dem Typenschild Die ausschlie liche Verwendung von geeignetem und unbesch digtem Werkzeug RDX VDX UDX RDX VDX UDX...

Страница 7: ...e sie so aus dass die L cher in der Schablone ber die Anschl sse passen Zeichnen Sie die Bohr l cher entsprechend der Schablone an und bohren Sie die L cher mit einem 6mm Bohrer Setzen Sie die mit gel...

Страница 8: ...n Die Wasser anschluss leitungen des Ger tes m ssen sich jedoch ohne Gewalt anwendung anschrauben lassen 3 Schrauben Sie die beiden Zoll berwurf muttern der Wasser anschluss leitungen des Ger tes jewe...

Страница 9: ...alt wasseranschlussst cke sind dann mit den 3 8 Zoll Dichtungen an die 3 8 Zoll berwurfmutter des Ger tes und des Auslaufrohres zu verschrauben Bei Aufputzmontage ist es sinnvoll das Ger t mittels der...

Страница 10: ...it einer Kontakt ffnungsweite von mindestens 3mm pro Pol vorzusehen z B ber Sicherungen Zur Absicherung des Ger tes ist ein Sicherungselement f r Leitungsschutz mit einem dem Ger tenennstrom an ge pas...

Страница 11: ...Elektroanschluss von unten Vergewissern Sie sich vor dem Anschlie en des Ger tes an das elektrische Netz dass die Stromversorgung ausgeschaltet ist 1 ffnen Sie die im oberen Ger te bereich vorhandene...

Страница 12: ...leitung und die Absicherung Beachten Sie zus tzlich die Vorgaben der DIN VDE 0100 1 Schalten Sie die Stromzufuhr zum Ger t ein Es erscheint die Leistungsanzeige 2 Beim ersten Einschalten der Versor gu...

Страница 13: ...betriebnahme Wird das Ger t nach der Erstinstallation unter einer anderen Installations umge bung abermals in Betrieb genommen so kann es not wendig werden die maxi male Ger te leistung zu ndern Durch...

Страница 14: ...aste zeigt den aktuellen Fehlercode an siehe Kurzdiagnose f r den Fachmann in der Ger tehaube Durch Dr cken der Pfeiltasten und k nnen nacheinander die letzten zehn Fehlercodes chronologisch angezeigt...

Страница 15: ...ionen 0 Beleuchtung immer an 1 Beleuchtung automatisch d h bei Tastendruck und Heizbetrieb an und nach einiger Zeit automatisch aus Werkseinstellung 2 Beleuchtung immer aus tL Temperaturlimit Die maxi...

Страница 16: ...Sie die Spannung an den Haussicherungen wieder ein Wartungsarbeiten d rfen nur von einem anerkannten Fachhand werksbetrieb durchgef hrt werden Reinigung und Wechsel des Filtersiebes im Anschlussst ck...

Страница 17: ...reusable materials and components Please respect in case of discarding that electrical devices should be disposed of separately from household waste at the end of their service life Therefore please t...

Страница 18: ...over Control panel support Connecting terminal Inlet pipe Cold water connection Water splash protection sleeve Grommet Screw in nipples inch Fine filter Flow limiter 5l min Frame DEX hood Non return v...

Страница 19: ...eating system Bare wire heating system IES Required spec water resistance 15 C 1300 cm Spec electrical conductivity 77mS m Inlet temperature 25 C Flow rate to switch on max flow rate 2 5 5 0l min 2 Pr...

Страница 20: ...hnical specifications Only intact and appropriate tools must be used For installations under difficult conditions these mounting accessories are available Mounting accessories Mounting kit RDX Art no...

Страница 21: ...late on the wall and align it so that the holes in the template fit over the connections Mark the drill holes according to the template and drill them using a 6mm drill Insert the included dowels 3 Sc...

Страница 22: ...the wall bracket However it must be possible to screw on the water connection pipes of the appliance without apply ing force 3 Screw the two inch union nuts of the appliance s water connection pipes e...

Страница 23: ...rewed into the 3 8 inch union nut of the appli ance and delivery pipe together with the 3 8 inch seals For direct connection it is advisable to mount the appliance at a distance as illustrated alongsi...

Страница 24: ...at the installation end To protect the appliance a fuse element must be fitted with a tripping current com mensurate with the nominal current of the appliance 2 1 4 5 3 7 Electrical connection Wiring...

Страница 25: ...an reinsert the faceplate Electrical connection from below Check that the power supply is switched off prior to electrical connection 1 Open the prepared breaking point S in the upper part of the appl...

Страница 26: ...of the local electricity supply company Germany DIN VDE 0100 1 Switch on the power supply to the appliance The digital display on the appliance must light up 2 When switching on the supply voltage fo...

Страница 27: ...Remove jumper 3 Put the appliance into operation again Reinstallation In case the appliance will be commis sioned again under different installation condi tions than during its initial ope ration it...

Страница 28: ...dicated by the first displayed value after pressing key refer to Abstract for Trouble Shooting Diagnostics in the hood By using the arrow keys and the last 10 error codes are displayed chronologically...

Страница 29: ...d and deactivated Setting options 0 Backlight always on 1 Backlight switches on automatically if button is pressed or water is heated preset 2 Backlight always off tL Temperature limit The maximum set...

Страница 30: ...emerges from the pipe 9 Fit the hood of the unit Then switch on the power again e g via activating the fuses Cleaning and replacing the filter strainer a closed open c b Strainer The cold water connec...

Страница 31: ......

Страница 32: ...ture limit on Dr cken Press 3 sek 1 2 Temperatur einstellen Set temperature 1 1 C 1 C Speicherwert w hlen Select preset temperature A1 A2 B1 B2 Temperatur speichern Store temperature 2 Dr cken Press 3...

Отзывы: