WS15P Parts and Service Manual

Troubleshooting Procedures

Problem

Possible Cause

Solution

1. No Display on PC Board

a. No power at electric outlet

a. Repair outlet or use working outlet

b. Control valve Power Adapter not plugged into 

outlet or power cord end not connected to PC 
board connection

b. Plug Power Adapter into outlet or connect 

power cord end to PC Board connection

c. Improper power supply

c. Verify proper voltage is being delivered to 

PC Board

d. Defective Power Adapter

d. Replace Power Adapter

e. Defective PC Board

e. Replace PC Board

2. PC Board does not display correct time of day

a. Power Adapter plugged into electric outlet 

controlled by light switch

a. Use uninterrupted outlet

b. Tripped breaker switch and/or tripped GFI

b. Reset breaker switch and/ or GFI switch

c. Power outage

c. Reset time of day. If PC Board has battery 

back up present the battery may be 
depleted. See Front Cover and Drive 
Assembly drawing for instructions.

d. Defective PC Board

d. Replace PC Board

3. Display does not indicate that water is 

fl

 owing. 

Refer to user instructions for how the display 
indicates water is 

fl

 owing

a. Bypass valve in bypass position

a. Turn bypass handles to place bypass in 

service position

b. Meter is not connected to meter connection on 

PC Board

b. Connect meter to three pin connection 

labeled METER on PC Board

c. Restricted/ stalled meter turbine

c. Remove meter and check for rotation or 

foreign material

d. Meter wire not installed securely into three pin 

connector

d. Verify meter cable wires are installed 

securely into three pin connector labeled 
METER

e. Defective meter

e. Replace meter

f. Defective PC Board

f. Replace PC Board

4. Control valve regenerates at wrong time of day

a. Power outage

a. Reset time of day. If PC Board has battery 

back up present the battery may be 
depleted. See Front Cover and Drive 
Assembly drawing for instructions.

b. Time of day not set correctly

b. Reset to correct time of day

c. Time of regeneration set incorrectly

c. Reset regeneration time

d. Control valve set at ”on 0” (immediate 

regeneration)

d. Check programming setting and reset to 

NORMAL (for a delayed regen time)

e. Control valve set at ” on 0” (delayed 

and/ or immediate)

e. Check programming setting and reset to 

NORMAL (for a delayed regen time)

5. Time of day 

fl

 ashes on and off

a. Power outage

a. Reset time of day. If PC Board has battery 

back up present the battery may be 
depleted. See Front Cover and Drive 
Assembly drawing for instructions.

6. Control valve does not regenerate 
automatically when the REGEN button is 
depressed and held.

a. Broken drive gear or drive cap assembly 

a. Replace drive gear or drive cap assembly

b. Broken Piston Rod

b. Replace piston rod

c. Defective PC Board

c. Defective PC Board

7. Control valve does not regenerate 
automatically but 

does

 when the REGEN button 

is depressed and held.

a. Bypass valve in bypass position

a. Turn bypass handles to place bypass in 

service position

b. Meter is not connected to meter connection on 

PC Board

b. Connect meter to three pin connection 

labeled METER on PC Board

c. Restricted/ stalled meter turbine

c. Remove meter and check for rotation or 

foreign material

d. Incorrect programming

d. Check for programming error

e. Meter wire not installed securely into three pin 

connector

e. Verify meter cable wires are installed 

securely into three pin connector labeled 
METER

f. Defective meter

f. Replace meter

g. Defective PC Board

g. Replace PC Board

Содержание WS15P

Страница 1: ...ETROLEUM JELLY KEROSENE BENZENE GASOLINE ETC WILL DAMAGE PRODUCTS THAT CONTAIN O RINGS OR PLASTIC COMPONENTS EXPOSURE TO SUCH HYDROCARBONS MAY CAUSE THE PRODUCTS TO LEAK DO NOT USE CLACK CONTROL VALVE...

Страница 2: ...Page 2 WS15P Parts and Service Manual...

Страница 3: ...ral Specifications 4 Drive Cap Assembly Pistons Stack Assembly Main Body 5 Regenerant Components 6 Injectors 7 Injector Flow Graphs U S Units 8 Injector Flow Graphs Metric Units 9 Fitting Kits 10 Drai...

Страница 4: ...gpm 15 psi drop 227 lpm 13 6 m3 h Backwash flow rate 43 gpm 25 psi drop 163 lpm 9 8 m3 h Meter Accuracy Flow Range 5 0 75 75 gpm 2 8 284 lpm Inlet Outlet 1 5 Male NPT or BSPT Drain line 1 Male Elbow N...

Страница 5: ...19 O RING 347 1 8 V4400 NPT WS15P NPT BODY ASSEMBLY 1 V4400 BSPT WS15P BSPT BODY ASSEMBLY 9 V4430 01 WS15P FTG ASY QC TO NPT 1 set of 2 V4430 02 WS15P FTG ASY QC TO BSPT 10 V3641 O RING 225 FOR VALVE...

Страница 6: ...15P Regenerant Components 1 Drawing No Order No Description Quantity 1 H4615 RETAINING CLIP 1 2 V3498 WS15 BRINE ELBOW ASY W RFC 1 3 V3195 01 REFILL PORT PLUG ASY 1 4 V4430 04NPT WS15P NPT DRAIN KIT 1...

Страница 7: ...iameter1 Quantity 1 V3010 15B WS1 5 Injector Asy B Violet 12 1 V3010 15C WS1 5 Injector Asy C Red 13 V3010 15D WS1 5 Injector Asy D White 14 V3010 15E WS1 5 Injector Asy E Blue 16 V3010 15F WS1 5 Inje...

Страница 8: ...5 2 2 5 3 20 40 60 80 100 120 Pressure psi Flow Rate gpm Total Slow Rinse Draw ORDER NO V3010 15E BLUE ORDER NO V3010 15B VIOLET ORDER NO V3010 15F YELLOW ORDER NO V3010 15G GREEN 0 5 1 1 5 2 2 5 3 2...

Страница 9: ...200 300 400 500 600 700 800 900 Pressure kPa Flow Rate lpm Slow Rinse Total Draw 2 4 6 8 10 100 200 300 400 500 600 700 800 900 Pressure kPa Flow Rate lpm Total Slow Rinse Draw 2 4 6 8 10 100 200 300...

Страница 10: ...ROL VALVE PRODUCT S ON WATER SUPPLIES THAT CONTAIN HYDROCARBONS SUCH AS KEROSENE BENZENE GASOLINE ETC Clack Order No V4430 01 Description WS15P QC to NPT Fitting Kit Drawing No Order No Description Qu...

Страница 11: ...62 053 5 3 GPM Drain line flow control V3162 065 6 5 GPM Drain line flow control V3162 075 7 5 GPM Drain line flow control V3162 090 9 0 GPM Drain line flow control V3162 100 10 0 GPM Drain line flow...

Страница 12: ...ce meter f Defective PC Board f Replace PC Board 4 Control valve regenerates at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be depleted...

Страница 13: ...water pressure water pressure must remain at minimum of 25 psi b Incorrect injector size b Replace injector with correct size for the application c Restricted drain line c Check drain line for restri...

Страница 14: ...t c Loosen main drive gear Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect d Imprope...

Страница 15: ...ze software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect d Foreign matter built up on piston and stack assemblies creating friction and drag enough to...

Страница 16: ...Page 16 WS15P Parts and Service Manual...

Страница 17: ...WS15P Parts and Service Manual Page 17...

Страница 18: ...Page 18 WS15P Parts and Service Manual...

Страница 19: ...oved V3190 series of DLFC from table and V3190 XXX drawing 7 6 2020 PAGE 11 All DLFC housings ship without DLFC installed Up to 5 x V3162 XXX DLFC may be installed in V4430 Select 1 5 flow controls fr...

Страница 20: ...shall be limited at its option to replacement or repair of any Softener and Filter Control valve covered by this Limited Warranty Prior to returning a Control Valve OEM must obtain a return goods aut...

Отзывы: