E.  Position the Drinking Water Holding Tank 

and Make the Final Hose Connections. 
1.  Check the tank precharge pressure. Make 

sure it is between 5 to 7 psig. If not, use a 

bicycle hand pump or other pump to bring the 

pressure up to the 5 to 7 psig range.

2.  Pull the cap/plug off the top of the tank where 

the Tank Shut–Off should go. (Refer to Fig. 

1.)

3.  Wrap Teflon tape three times around the ¼" 

male outlet thread. Wrap in the direction of 

the threads (clockwise when looking down 

on the Holding Tank). The tape will act as a 

thread sealant. Screw on the Holding Tank 

Shut–Off Valve.

4.  Locate the 

3

/

8

" Yellow Tubing. Firmly press 

one end into the Holding Tank Shut–Off Valve 

and the other end into the tee. (Refer to Fig. 

1.) The fittings will grab the tubing and seal 

it in place. Make sure the tubing is pressed 

all the way in to create a pressure tight 

connection. 

F.  Start Up 
  At time of start up and each time the filters are 

changed the system should be sanitized (also 

see Operation and Maintenance Sec. IV, B.1–4).
1.  Sanitizing the system and installing the 

Sediment Prefilter. Use a drip pan to aid 

clean–up. 

  NOTE: The system should be sanitized 

BEFORE installing the Activated Carbon 

Prefilter and the RO Membrane.
•Use a good quality unscented 5¼% liquid 

chlorine household bleach. 

•Open the Dispensing Faucet and open the 

Holding Tank Shut–Off Valve (the handle 

should be parallel with the valve body). 

•Remove the plug on the underside of the 

manifold labeled “SEDIMENT”. Pour one 

capful of bleach (this is approximately  

2 tsp. or 10 ml) into one of the white 

Housings. AVOID GETTING BLEACH 

ON THREADS AND O-RINGS. Unwrap 

Sediment Prefilter and install prefilter 

(O-rings up toward manifold.) Insert a 

Housing O–ring into the Housing groove, 

(press firmly in place). Engage and firmly 

tighten the Housing hand tight only.

•Remove the plugs labeled “ACTIVATED 

CARBON” and “MEMBRANE” from the 

underside of the manifold. To each of the 

remaining white Housings, add one capful 

of bleach. AVOID GETTING BLEACH ON 

THREADS AND O-RINGS. Insert a Housing 

O–ring, engage and firmly tighten the 

Housings hand tight only.

•Slowly open the Feed Water Saddle Valve 

(turning counter clockwise). 

•As soon as the water begins to come out of 

the Dispensing Faucet, close the Faucet.

•Let stand for 15 minutes. 
  NOTE: During this time, check the system 

carefully for leaks. 

•At the end of 15 minutes, CLOSE the 

Feed Water Saddle Valve and open the 

Dispensing Faucet. 

•Allow the Holding Tank to completely drain. 

Then remove the Activated Carbon Prefilter 

Housing (the middle one), empty, and install 

the Activated Carbon Prefilter. Firmly tighten 

the Housing hand tight only. 

2.  Installing the R.O. Membrane:

•Remove the R.O. Membrane Housing, (the 

closest of the three to In/Out ports), and 

empty. 

•Insert the Membrane up into the manifold. 

(The O–rings should be up toward the 

manifold.) Check the Housing O–ring for 

proper position in its groove, engage and 

firmly tighten the Housing hand tight only.

3.  Rinsing the system: 

•Slowly open the Feed Water Saddle Valve 

fully counter clockwise. 

•The Holding Tank Valve should be open.
•Check the Air Gap Window on the 

Dispensing Faucet to be sure that the drain 

water is flowing. The R.O. System is now 

making water.

•Do not open the Faucet for at least 8 hours.
•Do not use the first three full tanks of water.
  CAUTION: The R.O. Membrane is shipped 

with a preservative in it. To ensure proper 

rinsing of the R.O. Membrane it is important 

to wait at least 8 hours before emptying 

each tank.

Содержание T.F.C.-400

Страница 1: ...components critical for effective performance It is the user s responsibility to and the manufacturer strongly recommends that the user periodically test the product water to verify the system is per...

Страница 2: ...8 C Drain Clamp Installation 8 D R O Manifold Assembly Installation 9 E Position the Drinking Water Holding Tank and Make the Final Hose Connections 10 F Start Up 10 SECTION IV OPERATION AND MAINTENAN...

Страница 3: ...cess dissolved minerals are separated from the incoming water Feed Water to produce the product water the Permeate The excess minerals are rinsed to drain the Reject Water The membrane is a specially...

Страница 4: ...king water holding tank mount holding tank on shelf or strap between floor joists shelf or straps not included activated carbon pREfilter housing Reverse osmosis membrane housing sediment prefilter ho...

Страница 5: ...hours The production rate of a new Membrane can decrease by 10 per year or more depending upon the scaling and fouling tendencies of the Feed Water TABLE B RECOMMENDED OPERATING LIMITS FOR FEED WATER...

Страница 6: ...ller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch Clean away any chips Install the punch and tighten the nut to cut the hole Deburr any...

Страница 7: ...OLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fitting Push the Black 3 8 Polytube onto th...

Страница 8: ...til it is fully pierced When you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard Steel or Brass Tubing supply li...

Страница 9: ...and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRICTOR 2 Locate the Red Feed Water Tubing Remove the red plug from the fitting labeled In on the ma...

Страница 10: ...nd install prefilter O rings up toward manifold Insert a Housing O ring into the Housing groove press firmly in place Engage and firmly tighten the Housing hand tight only Remove the plugs labeled ACT...

Страница 11: ...ood idea to resanitize the system and to change the prefilter and post filters B Changing Filters THIS R O SYSTEM CONTAINS FILTERS WHICH MUST BE REPLACED AT REGULAR INTERVALS TO MAINTAIN PROPER PERFOR...

Страница 12: ...st 8 hours Discard the first three full tanks of water produced they will contain chlorine IN LINE ACTIVATED CARBON POST FILTER ASSEMBLY OUT IN In Line Activated Carbon Post Filter 3 8 Blue To Dispens...

Страница 13: ...13 NOTES...

Страница 14: ...14 NOTES...

Страница 15: ...15 NOTES...

Страница 16: ...eck The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Holding...

Страница 17: ...r in the Holding Tank Clean flush and sanitize the system Replace the filters The Product Water and Drain Water lines are reversed Correct plumbing Dissolved gasses in the Feed Water Pretreat Feed Wat...

Страница 18: ...18 MADE IN USA 15 Exploded View Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 18 17...

Страница 19: ...S7028 Activated Carbon Prefilter 13 S3069 Housing O Ring 14 S7029 09 Housing 15 S2116 5 Drain Restrictor 50 GPD 189 lpd 16 S1764RS T F C RO Membrane 50 gpd 189 lpd 17 S1405 1 4 3 8 Fitting Wrench 18...

Страница 20: ...harges You must also pay for shipping or travel charges to return the defective part s What Does This Warranty Not Cover This warranty does not cover the disposable sediment and carbon filters whose s...