X144 e-FlowMeter

Quick Start Installation & Removal Instructions 

7

6

5

10

9

8

Step 5: 

Insert straightened Swivel Insert/Measurement

Cylinder Assembly into valve, orient arrow on

wrench flat to point downstream

Step 6:

Loosen Thumb Set Screw. Remove Locking Collar

from tool. Remove tool and re-insert opposite end into

Swivel Assembly. Engage the tool and push firmly to orient

Measurement Cylinder 90˚ into flow path

Verify score mark is

flush with flat face

of straight thread

to ensure full

engagement

Step 7: 

Remove tool from Threaded Swivel Insert

Step 8: 

Insert tip of e-FlowMeter Sensor/Head Assembly

into Threaded Swivel Insert

Step 9: 

Line-Up Centering Groove on straight threads

with Centering Pin; push to seat o-ring

Centering

Groove

Centering

Pin

Knurled

Lock

Step 10: HAND TIGHTEN

Knurled Lock onto straight

threads. Attach Sensing Cable to Sensing Probe 

and Flow Display.

Proceed in accordance with Wiring Diagram

top view

inside view

flow

Step-By-Step X144D-AF e-FlowMeter Installation Instructions (continued)

Please see display 

programming manual for 

display configuration.