SM-A28840-A
1. PRODUCT OVERVIEW
5
2020-02-24
1.2.3 RCKL Series
Specification
Descriptions
RCKL
Cylinder bore size
mm
φ
40
Actuation
Double acting
Working fluid
Compressed air
Max.working pressure air
MPa
0.7
Min.working pressure air
MPa
0.3
Port size(Tube size)
Applicatable tube outer diameter
φ
4
(
With speed control valve
)
Ambient temperature
℃
5
〜
50
Operational stroke length
mm
10
Repeatability
mm
±
0.01
Product weight
kg
1.1
Sencor Specifications
Descriptions
Proximity 2-wire
T
2H
Applications
Programable controller
Load supply voltage
DC 10
〜
30V
Load current
5
〜
20mA
Indicator light
Gripper
Red LED
(
ON lighting
)
Flange
Blue
・
Green
Leakage current
1 mA or less
Shock resistance
980 m/s
2
Product weight
g
18
Gripping power performance data
Gripping power that functions to opening and closing directions for the length (
ℓ
) of attachment of gripper
at supply pressure 0.3,0.5,0.7MPa is shown. (Represent one finger)
・
Opening direction
( ) (
Dashed line indication
)
・
Closing direction
( ) (
Solid line indication
)
G
ri
pp
in
g
P
o
w
e
r
(N
)
L
Length (
ℓ
) of attachment (mm)