background image

[SM-200164-A/4]

8

ELECTRIC CIRCUITS (Section 5.4) 

a)  Check  for  the  presence  of  any  current  leak  from  the 

external  control  device  because  it  may  cause  an  er-
roneous valve operation. 

When  a  programmable  controller  or  a  similar  control  de-
vice  is  used,  a  current  leak  may  prevent  the  normal  re-
turning of the valve when the solenoid is de-energized. 

b)  Restriction on current leak 

When  controlling  solenoid  valves  using  a  programmable 
controller  or  a  similar  control device,  make  sure  that  the 
current  leak  in  the  programmable  controller  output  is 
equal  to  or  less  than  the  level  shown  in  the  table  below.   
A  current  leak  larger  than  the  allowable  level  may  cause 
an erroneous valve operation. 

PERIODIC INSPECTION (Section 6.1) 

Before  providing  a  maintenance  service,  cut  the  power 
and  the  supply  of  compressed  air  and  confirm  the  ab-
sence of residual pressure. 

The above is required to ensure safety. 

Regularly  perform  the  daily  and  periodic  inspections  to 
correctly maintain product performance. 

If  the  product  is  not  correctly  maintained  ,  product  per-
formance  may  deteriorate  dramatically,  resulting  in  a 
shorter  service  life,  fractures  of  components,  and  mal-
functions.

DISASSEMBLING AND REASSEMBLING (Section 6.2) 

Before  disassembling  and  reassembling  solenoid  valves, 
read the instruction manual carefully and understand the 
instructions. 

A  person  who  disassembles  and  reassembles  a  solenoid 
valve  system  needs  to  have  knowledge  for  safely  per-
forming such operation based on the understanding about 
the  mechanisms  and  operating  principles  of  solenoid 
valves. 

Personnel  involved  in  this  step  must  have  passed  the 
Pneumatic Pressure Skill Test Class 2 or higher. 

 

CAUTION : 

AC100V 

3.0 mA or lower 

AC200V 

1.5 mA or lower 

DC24V 

1.8 mA or lower 

CR circuit

Leakage

current

Solenoid valve

Contact

C

R

Programmable
controller 

 

CAUTION : 

 

WARNING : 

 

WARNING : 

Содержание MN4KB1 Series

Страница 1: ...ead this instruction manual carefully before using this product particularly the section describing safety Retain this instruction manual with the product for further consultation whenever necessary 4...

Страница 2: ...product is intended for use in general industrial devices and parts Use beyond such conditions is not considered Consult with CKD for details when using the product beyond the unique specification ra...

Страница 3: ...umatic components make sure that system safety such as pop out prevention measures is secured 5 Observe warnings and cautions on the pages below to prevent accidents The safety cautions are ranked as...

Страница 4: ...nd those stated in the catalogue or specifications Failure resulting from malfunction of the equipment and or machine manufactured by other companies Failure resulting from wrong use of the product Fa...

Страница 5: ...enoid valve system dry Take care to avoid direct contact with dripping water or splashes of cutting oil If the solenoid valve system is wet by a direct contact with water or cutting oil an electrical...

Страница 6: ...ing and gaskets may deteriorate sooner than usual if used in an atmosphere with a higher than normal density of ozone for example the atmosphere near a beach or in an area with frequent thunder storms...

Страница 7: ...ly pressurized air may disconnect pipes at joints and or cause the tubes to jump around any of which may cause an injury d Do not decrease the inside diameter of the piping from any of the solenoid va...

Страница 8: ...the cylinder to be acti vated AIR QUALITY Section 5 3 a Do not supply anything other than compressed air b Supply clean compressed air without any mixture of corrosive gas a Compressed air usually co...

Страница 9: ...irm the ab sence of residual pressure The above is required to ensure safety Regularly perform the daily and periodic inspections to correctly maintain product performance If the product is not correc...

Страница 10: ...od 14 4 3 Piping 15 4 4 Wiring 18 5 OPERATING RECOMMENDATION 5 1 Operation 24 5 2 Manual operating device 26 5 3 Air Quality 27 5 4 Electric Circuits 29 6 MAINTENANCE 6 1 Periodic Inspection 30 6 2 Di...

Страница 11: ...ecting key The key is pushed in after the connection of the blocks in order to secure the connection Mounting screw DIN rail on the manifold DIN rail End block It has a function of common supply exhau...

Страница 12: ...9 80665 10 2 1 10 2 1 Note 1Pa 1N m2 1MPa 1N mm2 Pressure Pa kPa MPa bar kgf cm2 atm mmH2O mmHg or Torr 1 1 10 3 1 10 6 1 10 5 1 01972 10 5 9 86923 10 6 1 01972 10 1 7 50062 10 3 1 103 1 1 10 3 1 10...

Страница 13: ...valves are ready to be con nected to the pipes the entry of foreign matter from the piping ports could cause the solenoid valves to fail or malfunction a Check the model number imprinted on the produ...

Страница 14: ...lt Protect the solenoid valve system by using a cover or by installing it inside a paneled casing If the cylinder rod is splashed with cutting oil the oil may penetrate through the cylinder into the s...

Страница 15: ...h frequent thunder storms Consult us for the packing and gaskets to be used in an atmosphere with a higher ozone density 4 2 Installation method When installing a solenoid valve unit never attempt to...

Страница 16: ...ighly pressurized air may disconnect pipes at joints and or cause the tubes to jump around any of which may cause an injury d Do not decrease the inside diameter of the piping from any of the solenoid...

Страница 17: ...y in the cylinder response If such a delay hap pens the speed needs to be adjusted between the cylinder and solenoid valve 4 3 4 Pipe connections 1 Tubes to be used For use with solenoid valves with o...

Страница 18: ...Neglecting the minimum bending radius may cause disconnection or leaks Tube bore Minimum bending radius mm Nylon Urethane 4 10 10 6 20 20 8 30 30 10 40 40 6 Cutting a tube To cut a tube use a tube cu...

Страница 19: ...oltage and the current type AC or DC 1 Caution for wiring 1 When using the small terminal box and water proof is required use cab tire cords 4 to 6 5 in outer diameter water resistance is improved but...

Страница 20: ...code B L LS Shape Circuit Name Plug in connector C type with lead wire Plug in connector C type without lead wire Plug in connector C type with lead wire surge suppressor and indicator light Plug in c...

Страница 21: ...sor and indicator light Plug in connector D type without leadwire surge suppressor and indicator light Option code D D1 D2 D3 Shape Circuit Name Surge suppressor attached Option code S Shape DC only g...

Страница 22: ...No 4K9 013 Caulking tool Tyco Electronics Japan 720781 3 Earth terminal Coil Lead wire 0 3 to 0 75mm2 Cabtyre cord JIS C3306VCTF 2 cord Outside diameter 4 to 6 5 Cap Washer Gasket Pin support Case Se...

Страница 23: ...inguish plus or minus Lead wire 0 3 to 0 75mm2 Connect element wire with screw It may be necessary to provide a small standard driver Eliminate connecting surge suppressor together Slide the gasket an...

Страница 24: ...rminal made by CKD Caulking tool made by CKD Lead wire AWG22 to 25 0 16 to 0 38mm2 Terminal caulking Insert both caulked terminals into the slots farthest apart Insert a socket Insert a gasket and con...

Страница 25: ...rom P to B Exhaust from A to R Air supply from P to A Exhaust from B to R 4KB129 Air supply from P to A Exhaust from B to R 4KB139 Closed P A B R 4KB149 Closed P Exhaust from A B to R 4KB159 Air suppl...

Страница 26: ...ends to atmosphere 3 The adjoining cylinder may pop out by back pressure when driving the sin gle acting cylinder with 3 position A B R parts connected 4KB140 or 3 port valve in the manifold To preven...

Страница 27: ...ly return to OFF position 1 Manual operating device As this is a pilot solenoid valve the spool will not be switched by operating the manual operating device without an air supply to the P port 2 Non...

Страница 28: ...tion 5 3 1 Lubrication The MN4KB1 Series solenoid valve systems use pre lubricated valves that usually do not require lubrication from the outside If you have to lubricate a valve use Type 1 turbine o...

Страница 29: ...il wear of the sliding components of the pneumatic device may be acceler ated 2 Supply clean compressed air that does not include solid foreign matter 1 Solid foreign matter in the compressed air may...

Страница 30: ...w A current leak larger than the allowable level may cause an erroneous valve operation 1 With a double solenoid type valve system energize the solenoid for at least 0 1 second even for an instantaneo...

Страница 31: ...from the air filters 1 Checking the compressed air supply pressure Is the supply pressure at the specified level Does the pressure gauge indicate the specified pressure when the system is operating 2...

Страница 32: ...olenoid valve system needs to have a knowledge for safely per forming such operation based on the understanding about the mechanisms and operating principles of solenoid valves 6 2 1 Solenoid valve mo...

Страница 33: ...block mounting 1 First confirm that the fixing screws are loose Push the block from above and get the movable claw hooked onto the rail 2 Lift the block to see the claw is firmly in place 3 Tighten th...

Страница 34: ...en push the moveble claw from above 2 Slie them until there is no space between the blocks and push in the connecting key 5 Air supply exhaust block valve block detaching 1 Remove the end block 2 Pull...

Страница 35: ...stall pipe joints to A and B ports with diame ter equal to or smaller than that of to P port joint Valve is frozen Add remedies of avoiding freezing Heating system or dehumidifying system etc Delayed...

Страница 36: ...ing pressure MPa 0 70 Proof pressure MPa 1 05 Response time ms 30 or less 2 pos 60 or less 3 pos Lubrication Not required Use Grade turbine oil type 1 ISO VG 32 when required Protection structure Dust...

Страница 37: ...indicator light No option 25 25 stations LS Small terminal box with surge suppressor and indica tor light No option C Plug in connector C type 300mm C00 500mm C01 1000mm g Voltage C02 2000mm Code Des...

Страница 38: ...after the ordinary model description Also state after the model description the marking see the table of necessary functions and position numbers starting with 1 on the left side until the specified n...

Страница 39: ...nector C type with surge suppressor and indi cator light 300mm DC24V DC24V C20 500mm AC24V AC24V 50 60Hz Option C21 1000mm AC110V AC110V 50 60Hz C22 2000mm AC115V AC115V 50 60Hz C23 3000mm AC120V AC12...

Страница 40: ...Right side end block 2 Air supply exhaust block NQ Model no P port R port PR port N4KB1A NQSH8 8 8 8 N4KB1A NQSH886 8 8 6 N4KB1A NQSH686 6 8 6 N4KB1A NQSH6 6 6 6 Model no P port R port PR port N4KB1A...

Страница 41: ...6 6 Model no P port N4KB1A NPUH8 8 N4KB1A NPUH6 6 4 Exhaust block NR Model no R port PR port N4KB1A NRSH8 8 8 N4KB1A NRSH86 8 6 N4KB1A NRSH6 6 6 Model no R port PR port N4KB1A NRUH8 8 8 N4KB1A NRUH86...

Страница 42: ...no A B port N4KB1A NS2SH8 8 N4KB1A NS2SH6 6 N4KB1A NS2SH4 4 NS is provided according to a Solenoid position When changing solenoid position NS should be changed 6 Partition block NC Model no Descripti...

Страница 43: ...Related equipment Mounting rail Model no L BAA500 500 BAA1000 1000 Silencer Model no D L SLW H6 6 41 23 5 SLW H8 8 42 23 Blank plug Model no D L d GWP4 B 4 27 11 6 GWP6 B 6 29 11 5 8 GWP8 B 8 33 14 1...

Страница 44: ...10 4K9 110 4KB110 4K9 151 4KB120 4K9 118 4KB120 4KB130 4K9 111 4KB130 4K9 152 4KB140 4K9 112 4KB140 4KB150 4K9 113 4KB150 3 Coil assembly Function Model example All model common 4K1L COIL 4 Gasket kit...

Отзывы: