[SM-200164-A/4]
−
38
−
SPECIFICATION
HOW TO ORDER
8
8.2.2 N4KB1
(a)
(b)
(c)
(d)
(e)
(f)
Operation classification Solenoid valve
(a) Operator type
(b) Port size
(c) Manual operating device
Code
Description
Code
Description
Code
Description
1
2-pos.single operator
H4
φ
4 push-in joint
No code Non-lock type manual operating
device
2
2-pos.double operator
H6
φ
6 push-in joint
M1
Lock type manual operating
device
3
3-pos.all ports blocked
H8
φ
8 push-in joint
4
3-pos.load ports open to exhaust
ports
5
3-pos.load ports open to supply ports
(d) Electric connection
(e) Other options
Code
Description
Lead wire
Code
Description
No code Grommet with lead wire
300mm
No code No option
B
Small terminal box
No option
S
Surge suppressor attached
(Only grommet with lead wire)
L
Small terminal box, with indicator
light
No option
LS
Small terminal box,
with surge suppressor and indi-
cator light
No option
C
Plug-in connector C type
300mm
C00
500mm
C01
1000mm
(f) Voltage
C02
2000mm
Code
Description
C03
3000mm
AC100V
AC100V 50/60Hz
Standard
C1
No option
AC200V
AC200V 50/60Hz
C2
Plug-in connector C type
with surge suppressor and indi-
cator light
300mm
DC24V
DC24V
C20
500mm
AC24V
AC24V 50/60Hz
Option
C21
1000mm
AC110V
AC110V 50/60Hz
C22
2000mm
AC115V
AC115V 50/60Hz
C23
3000mm
AC120V
AC120V 50/60Hz
C3
No option
AC220V
AC220V 50/60Hz
D
Plug-in connector D type
300mm
DC12V
DC12V
D00
500mm
D01
1000mm
D02
2000mm
D03
3000mm
D1
No option
D2
Plug-in connector D type
with surge suppressor and indi-
cator light
300mm
The attached surge suppressor is suppression type (Diode)
only for the grommet with lead wire of below DC 24V.
D20
500mm
D21
1000mm
If DC voltage type is selected for (f), L will be provided
with a builtin surge suppressor for DC voltage.
D22
2000mm
D23
3000mm
The AC100 and 200V coil can be used for AC110V (60Hz)
and AC220V (60Hz), respectively.
D3
No option
NOTE: Following options are available as a custom order.
・
Ozone-proof specifications
Available in ozone-proof specifications by adding -P11 to the end of model number. Model number:
※※
-Voltage-P11
・
Coolant proof specifications
Selectable with option symbol A. Model number:
※※
-A-Voltage
・
Copper and PTFE free (Copper and PTFE materials are not used for flow path)
Available in copper and PTFE free by adding -P6 to the end of model number. Model number:
※※
-Voltage-P6
0A
1
N4KB1
M1 B
H4
S
AC100V