CKD FGRC Series Скачать руководство пользователя страница 12

SM-A14448-A/2 

2. INSTALLATION 

 

2019-08-19 

 

WARNING 

Do not install the product to a combustible material. 

If the product is installed directly to or near a combustible material, a fire may result. 

If the system is such that the machine stops in the event of a system failure such as an 
emergency stop or a power failure, design and implement a safety circuit or a safety device to 
prevent damages to the devices and injuries to people. 

Install a safety fence to prevent entry into the actuator movable range. 
Perform class D grounding (ground resistance: 100 Ω or less) for the product. 

An electric leakage may occur and cause an electric shock or malfunction. 

When wiring the product, refer to this Instruction Manual or any other relevant instruction 
manuals to make sure that the connectors are firmly connected and the wires are properly 
insulated. 

Make sure that the wires do not contact other circuits and there is no ground fault and insulation 
failure between terminals. Otherwise, an overcurrent may flow into the product and cause damage. 
This may result in an abnormal operation or fire. 

Insulate unused wires. 

A malfunction, failure, or electric shock may occur. 

Do not damage or pinch the cables, apply unnecessary stress to the cables, or place heavy 
objects on the cables. 

A conduction failure or electric shock may occur. 

Do not connect the communication connector of the product to other devices. 

A malfunction or damage may occur. 

Make sure to install the emergency stop button in a location where operation is easy. 

Adopt a structure and wiring system that inhibit any automatic resetting of emergency stop button, 
and that prevent a person from accidentally resetting the emergency stop button. 
When an emergency stop is executed, it may take several seconds until the machine has actually 
stopped, depending on the travel speed and carrying load. 

Install the product indoors and in a dry place. 

In a place where water can splash onto the product or where humidity is high (80% or more and 
with condensation), an electric leakage or fire accident may occur. 

Do not use or store the product in an environment where there is strong electromagnetic 
waves, ultraviolet rays, or radiation. 

A malfunction or failure may occur. 

Consider the possibility of power source failure. 

Implement measures so as to prevent injuries to people and damages to devices even if a failure 
occurs with the power source. 

Consider the possibility of motor failure. 

Consider the operating state when restarting the product after an emergency stop or an 
irregular stop. 

When there is a need for resetting the actuator to the starting position, design a safe control 
unit. 

Because precision instruments are integrated, do not lay the product sideways or subject the 
product to vibration or impact during transportation. 

Component damage may occur. 

Do not stand on the product, use it as a foothold, or place an object on it. 

A  fall  accident,  injury  due  to  the  product  falling  down  or  off,  or  malfunction  due  to  the  product 
becoming damaged may occur. 

 
 

 

Содержание FGRC Series

Страница 1: ...ead this Instruction Manual before using the product Read the safety notes carefully Keep this Instruction Manual in a safe and convenient place for future reference SM A14448 A 2 MSV 484083 Electric...

Страница 2: ...nge without notice The product is intended for users who have basic knowledge of materials wiring electricity and mechanisms CKD shall not be responsible for accidents caused by persons who selected o...

Страница 3: ...ident To avoid this Thoroughly read and understand this Instruction Manual before using the product To explicitly indicate the severity and likelihood of a potential harm or damage precautions are cla...

Страница 4: ...man life and body Mechanism and mechanical device for transferring and transporting people Critical parts for securing safety in a mechanical device WARNING Use the product within the specifications P...

Страница 5: ...fixed movable 4 1 5 Specifications 5 2 INSTALLATION 6 2 1 Environment 10 2 2 Unpacking 10 2 2 1 Parts of the product 10 2 3 Installing 11 2 3 1 Actuator 11 2 3 2 Objects transferred table upper surfac...

Страница 6: ...power supply EA PWR KHNA480F 48 Surge protector AX NSF RAV 781BXZ 4 Noise filter AX NSF NF2015A OD Ferrite core 7 pieces EA NSF FC01 SET Provided for free Software for Windows S Tools PC setting soft...

Страница 7: ...following Part name No Electric actuator ECR controller SM A10615 Electric actuator ECR controller IO Link specification SM A10616 Electric actuator ECR controller CC Link specification SM A10617 Elec...

Страница 8: ...SM A14448 A 2 1 PRODUCT OVERVIEW 3 2019 08 19 1 4 Model Number Indication 1 4 1 FGRC Series...

Страница 9: ...SM A14448 A 2 1 PRODUCT OVERVIEW 4 2019 08 19 1 4 2 Motor cable fixed movable 1 4 3 Encoder cable fixed movable...

Страница 10: ...r power supply voltage 48 24 VDC 10 Motor section instantaneous maximum current Note 2 A 1 4 3 0 4 2 Weight kg 0 65 1 05 1 85 Insulation resistance 10 M 500 VDC Withstand voltage 500 VAC 1 minute Oper...

Страница 11: ...nt capacity as a power supply for the controller and the input output circuit If the product is directly connected to an AC power supply a fire burst or damage may occur Do not work with wet hands An...

Страница 12: ...unction or damage may occur Make sure to install the emergency stop button in a location where operation is easy Adopt a structure and wiring system that inhibit any automatic resetting of emergency s...

Страница 13: ...d Remove all the FG frame ground connections of the product before performing electric welding on the device to which the product is installed If electric welding is performed without removing the FG...

Страница 14: ...d mount the jigs Do not hold the controller case tightly When using positioning holes make sure to use pins having the size that does not require press fitting If press fitting sized pins are used the...

Страница 15: ...th dents The controller is set using setting software S Tools Leave a space of 70 mm or more in front of the controller so that the connector of the connection cable of the PC can be connected and dis...

Страница 16: ...of the bolt for installing the body refer to the following table 2 3 2 Objects transferred table upper surface The flatness of the workpiece attached to the table should be 0 02 mm or less Do not appl...

Страница 17: ...f or malfunction and runaway due to the product becoming damaged may occur Take measures to prevent damage to the human body and the device in case of power failures An unexpected accident may occur B...

Страница 18: ...into the opening of the product An injury or product damage may occur When replacing either the actuator or the controller in a combination make sure to check the program and parameters before operati...

Страница 19: ...ot apply excessive load to the manual operation plate An operation fault or damage may occur The manual operation is mainly intended for use in starting maintenance and inspection If used too often an...

Страница 20: ...or the lead wires used for the power cable use wires with a sufficient diameter that can allow the instantaneous maximum current to flow A heat generation or damage may occur during operation Perform...

Страница 21: ...heck that there are no scratches and cracks on the cables Visual inspection Replace the cable 3 Check that foreign matters are not accumulating or are not stuck in between the movable section Visual i...

Страница 22: ...ck the details of the alarm The details of the alarm can be checked with the setting software S Tools 5 Check the state of the I O The state of the I O can be checked with the setting software S Tools...

Страница 23: ...t connection Wiring is not correct Refer to Chapter 4 in Controller Instruction Manual SM A10615 and check the wiring Product does not operate as intended with PLC signal Input signal is unstable Inpu...

Страница 24: ...ing completion output does not turn off Positioning completion output width is too large compared to travel distance Check the Positioning width in the point data Pressing operation cannot be performe...

Страница 25: ...ntrol of CKD The warranty stated herein covers only the delivered product itself Any loss or damage induced by failure of the delivered product is excluded from this warranty Confirmation of product c...

Отзывы: