20
Connection to the programmable controller
The connection method depends on the type of the programmable controller. Connect as shown below.
Ex. 10 - Power supply noise absorption circuit
C
1
=20 μF to 50 μF electrolytic capacitor
(withstand voltage 50V or more)
C
2
=0.01 μF to 0.1 μF ceramic capacitor
R
1
=20 Ω to 30 Ω
- Starting current restriction resistor
R
2
= Highest possible resistance for the load circuit.
- Wire near the switch (within 2 m)
Switch
Within 2m
C
1
C
2
R
1
R
2
+
Brown
Black
Blue
Blue
Brown
Switch
Switch
COM
F2, F2Y connection to source input (internal power)
Blue
Brown
Input
termi-
nals
Programmable controller
F2, F2Y connection to source input (external power)
Blue
Brown
Switch
Switch
Programmable controller
Blue
Brown
COM
Input
termi-
nals
Brown
Blue
Switch
Switch
COM
Brown
Blue
Programmable controller
Input
termi-
nals
F2, F2Y connection to sink input (external power)
Switch
Brown
Black
Blue
COM
24 VDC
External
power
Programmable controller
Input
termi-
nals
F3, F3Y connection to source input (external power)
Switch
Brown
Black
Blue
COM
24 VDC
Programmable controller
Input
terminals
F3, F3Y connection to source input (internal power)