Cleaning of Condenser
•
The condenser looks like a
radiator and is located on the left
side of a refrigerated product.
•
Remove 4 screws on bottom
cover panel. Vacuum the
condenser coils on. Replace lower
panel.
•
You should be able to shine a
flashlight on the outside of the
coils and see the beam inside,
when the coils are clean.
•
Excess dirt or poor ventilation can
cause no cold water and
compressor cycling on the
compressor overload protector.