Specifications 
 
Dimensions: 

 18.50” x 5.218” x 8.50” 

 
Weight:

  13.5 Lbs. 

 

Electrical Specifications: 

  Input Power 100-240VAC 50/60 Hz 600 Watts 

  Output Power 24VDC 20Amps Max 

 
Features:   

  Heavy Duty NEMA 1 Steel and Aluminum enclosure 

  100-240 VAC 50/60hz Mains Power (auto-ranging) 

  Mounting points for C-Clamps & Safety Cable 

  (12) 4P XLRF  CK Data/24V Power output connectors for fixture connection 

  DMX 512 Interface (see below) 

  1 x 750 Watt internal power supply  

  24VDC 3A current limited per circuit output with LED Fault Indication 

  One-touch Mini-Zapi feature for reconfiguring fixtures with correct starting DMX Address  

  Includes 7 types of user-configurable fade and chase routines for stand-alone operation 

  In Stand-Alone Mode, selected routine is output to DMX Pass-Thru for synchronized 

Stand-Alone operation of many CB Supply systems 

 
DMX 512 Interface:

   

  DMX Input via 5P XLR Male 

  Isolated and repeated DMX Pass-Thru via 5P XLR Female 

  DMX Address interface utilizing 3 Rotary BCD Switches for DMX Address  configuration 

 

CK Output Configuration 
 

  12 outputs providing Color Kinetics control protocol, +24VDC, and Ground 

  “CB Mode”: DMX converted to CK protocol and output selectively to each port as per 

BCD address setting (see below)  

   “iCove Mode”:  All 512 DMX values converted to CK Protocol and output on all ports 

 

Options: 

 

Rack mount  

 

Terminal Block Output 

 

4P XLR Output 

 

Pipe Mount 

 

ETL/cETL Version 

 

CE Version 

 
*Fixtures Supported:  

ColorBlast 12, ColorBlast 6, ColorBurst 6®, ColorBurst 4®, iColor Cove® 

 
 

 

Содержание Color Kinetics PDS-750-TR

Страница 1: ...PDS 750 TR Touring Power Supply Operator s Manual Rev 1 2 2004 City Theatrical Inc Patent Pending ...

Страница 2: ...el Features 5 Mains Power Requirements 5 Connecting Color Kinetics fixtures to the PDS 750 TR 5 Operating Modes CB Pass Thru or Stand Alone 6 CB Mode 6 Pass Thru Mode 6 Stand Alone Effects Mode 7 Using the Mini Zapi 10 Installing the PDS 750 TR 10 Software Options 11 Specifications 12 FIGURES Figure 1 PDS 750 TR Front Panel 4 Figure 2 PDS 750 TR Back Panel 5 Figure 3 PDS 750 TR with C Clamps 10 ...

Страница 3: ...door use only Keep the unit dry Do not operate the unit if it gets wet Do not operate in excessive heat direct sunlight Be sure installation provides adequate ventilation Both the front and the back side of the unit must be clear of obstruction and allow free airflow There are no user serviceable parts inside Refer to qualified service personnel Compliance Certifications ETL Listed Conforms to UL ...

Страница 4: ...hru Mode Alternating Red Green Stand Alone Mode 2 Reset Switch Press to reset the PDS 750 TR s system microprocessor 3 DMX Address Switches Left to right 100 s 10 s 1 s Set address to 000 for Pass Thru mode Set address to any valid address 001 4761 for CB mode 4 Configuration Switch Selects Stand Alone Routines Also may be used for special functions 5 Channel Overload Indicator Lights if internal ...

Страница 5: ...male Panel Mount connector a re generated optically isolated DMX output the Unit switches to passive hard wired pass thru if power is lost 10 Fixture Output 1 4P XLR Female for connection of Color Kinetics fixtures 11 Fan do not obstruct 12 Fuse 10A 3AG Mains Power Requirements The PDS 750 TR is is compatible with 100 240 VAC 50 60 Hz Mains Power The unit is provided with a panel mount IEC Input c...

Страница 6: ...er of the output that fixture is connected to With the DMX Address set to 001 Fixture 1 DMX 1 2 3 Fixture 2 DMX 4 5 6 etc To put the unit into CB Mode simply set the DMX Address switches to a desired address other than 000 The unit can be set to any valid DMX address however please note that any starting address over 476 will disable some outputs Configuration system setup for CB DMX managed mode ...

Страница 7: ... the DMX Address switches and the Config switch Configuration Switch Settings for different Stand Alone Effects 0 No Stand Alone function The System will operate normally in Pass Thru or CB Modes depending on the DMX Address switch settings 1 Fixed Color The DMX address BCDs are used to adjust the red green and blue components DMX 100s controls the red 0 is off and 9 is full DMX 10s controls green...

Страница 8: ...enta Red 4 Cross Fade The Cross Fade effect changes from one preset color to another than back again The DMX 100s switch sets the starting color and the DMX 10s switch sets the ending color The user specified speed is controlled by the DMX 1s switch The following speeds are provided 0 5 sec 1 10 sec 2 30 sec 3 1 min 4 2 min 5 15 min 6 30 min 7 1 hr 5 The random color effect produces random colors ...

Страница 9: ...3 Yellow 4 Blue 5 Magenta 6 Cyan 7 White 8 9 Black The strobe rate is controlled by the DMX 1s digit The following rates are provided 0 20 sec 1 13 sec 2 10 sec 3 7 5 sec 4 5 sec 5 4 sec 6 3 sec 7 2 sec 7 Variable color strobe steps from color to color Red Green Yellow Blue Magenta Cyan White in a user definable time period at a strobe rate that is also user definable The same strobe rate that is ...

Страница 10: ... stops Power the system down 7 Power the system back up to test the units Installing the PDS 750 TR The PDS 750 TR can be mounted to a pipe or truss using standard theatrical C clamps The Unit is provided with holes on each side of the case cover for attaching the C clamps and with a hole in the left edge of the case cover for a safety cable When mounting the PDS 750 TR in this way all necessary c...

Страница 11: ...ddress the second light as the CTI min zapi will only address units as CK Light 1 2 Stand Alone features are not available with Ver 1 04 software Version 1 04a This is a low noise version that is otherwise identical in operation to 1 04 With version 1 04a the PDS 750 only outputs level changes to the fixture ports Since the CB fixtures hold the last the valid level data level sent until they recei...

Страница 12: ...igurable fade and chase routines for stand alone operation In Stand Alone Mode selected routine is output to DMX Pass Thru for synchronized Stand Alone operation of many CB Supply systems DMX 512 Interface DMX Input via 5P XLR Male Isolated and repeated DMX Pass Thru via 5P XLR Female DMX Address interface utilizing 3 Rotary BCD Switches for DMX Address configuration CK Output Configuration 12 out...

Отзывы: