If the telephone wire condition is clean (no bundled wires) the noise level will be
less than 3 and the peak level of the normal signal is about 50 hexes. But in strong
cross-talk environments the noise level is sometimes as high as 10 to 15, in this case the
noise floor (Register 23, the Noise Control Register) will be set to 1A to avoid cross talk
noise.
But in some reflection signal (noise) case, the normal signal has been cancelled by
the reflection signal original from the real signal. So the peak signal may be only 8 to 10.
So the Noise floor has to be set to about 5.
For example: Please refer to Figure A; port 1 value is PC01R23:0CFF, the noise
level is 0C, to change this value form 0C to 0A, using the following command:
WP01R23H0AFF.
Please save the new value with the “
S
” command after finished
issuing commands.