background image

Troubleshooting 

 

Problem Possible 

Cause 

Remedy 

Battery discharged 
 

Charge battery for 8 
hours or more. 

Battery defect 

Battery replacement. 

No LED display 

Power switch is not 
pressed 

Press and hold power 

switch. 

AC Input is missing 

Check AC input 
connection. 

Mains normal but 
works in inverter 
mode 

Input protector is 
effective 

Reset the input 
protector. 

Alarm buzzer beeps 
continuously  

Overload 

 

Verify that the load 
matches the capability 
specified in the specs.   

Overload 

 

Remove some 
non-critical load. 

Back up time is 
shorten 

Battery voltage is too low.  Charge battery for 8 

hours or more. 

 
If any abnormal situations occur that are not listed above, please call service 
technician immediately. 

Содержание CPI-1000 Series

Страница 1: ...USER MANUAL CiTO Power INVERTERS Series CPI 500 CPI 1000...

Страница 2: ...es must be rated for 75o C or higher and should be no less than 10AWG gauge The inner diameter of the copper ring terminal which is used to connect battery cables to Inverter DC terminals should be no...

Страница 3: ...is connected to a wall socket utility power goes to connected equipment s and or charges the battery set via charging system In UPS mode Inverter automatically converts battery energy into AC power f...

Страница 4: ...atically and works in mains mode or inverter mode according to input AC source s status When press this button again Inverter will turn off automatically Mains Mode LED The green LED will blink or lig...

Страница 5: ...tor Three station Terminal Block 4 Output Receptacle s 5 Input Voltage Range Selector Input voltage range is defined in specification chapter and output voltage is the same as input voltage in mains m...

Страница 6: ...inal Tighten the M5 nut Do not place anything between the flat part of battery terminal and the battery cable ring terminal or overheating may occur Figure 4 Battery Cable Connections to CPI 500 1000...

Страница 7: ...otal output voltage This voltage MUST match the DC voltage requirements of the CiTO unit or damage may occur to both the CiTO unit and or the batteries z Parallel Connection Wiring batteries in parall...

Страница 8: ...e is disconnected before attempting to connect AC power cables and load to Inverter Step 2 Connect the hot wire black brown of AC input cable to the HOT IN terminal Step 3 Connect the neutral wire whi...

Страница 9: ...Voltage 12Vdc 24Vdc Charging Voltage 13 7V 27 4V Charging Current 8A max 6A max CHARGER Overcharging Protection 14 5V 29V TRANSFER Transfer Time 8ms typical Line mode Green LED blinks or lights stead...

Страница 10: ...connection Mains normal but works in inverter mode Input protector is effective Reset the input protector Alarm buzzer beeps continuously Overload Verify that the load matches the capability specified...

Отзывы: