background image

 

- 30 -

 

 

 

Product Specifications

 

 

○ GPS antenna

 

Case

 

Polycarbonate resin, light gray

 

Receivable radio waves

 

GPS satellite radio waves/quasi-zenith satellite radio waves, L1 band

 

Receivable frequency

 

1575.42MHz

 

Reception sensitivity

 

-145dBm (during cold start)

 

Temperature range for 
use

 

-20℃ to 60℃

 

Protection level

 

Equivalent to IP44

 

Installation bracket

 

Stainless steel

 

Weight

 

Approx. 0.5kg (including 5m cable)

 

 

○ Signal cable (between antenna signal converters, up to 600m)

 

Cable color

 

Description

 

Green

 

RX-

 

White

 

RX+

 

Black

 

GND

 

Red

 

V+

 

Shield

 

SG

 

 

○ Signal converter (time server)

 

Case

 

AES resin, light gray

 

Input signal

 

Serial signal

 

Output signal

 

(1) Semiconductor relay output signal:    2 systems

 

      The output circuit is turned on for 2 seconds every hour on the hour

 

(2) Network interface:    1 system

 

      NTPv3/v4,  SNTPv3/v4

 

      RJ45    10BASE-T, 100BASE-TX

 

Reception status

 

LED display

 

Temperature range for 
use

 

0 to 40℃

 

PoE power input

 

IEEE802.3af compliant

 

Power consumption

 

2.2W (maximum)

 

Weight

 

Approx. 0.2kg

 

 

○ AC adapter

 

Input voltage

 

100V-240V    50/60Hz

 

Output voltage

 

DC15V    0.4A

 

Weight

 

Approx. 0.1kg

 

 

○ Hazardous substance regulations

 

Compliant with the RoHS Directive

 

 

Содержание TSV-400GP

Страница 1: ......

Страница 2: ...1 You can download the English version of this instruction manual from the URL below http tic citizen co jp timeserver...

Страница 3: ...GP can be used to periodically synchronize the time of various devices by turning on the regular time semiconductor relay output circuit The TSV 400GP supports IEEE802 3af compliant PoE Power over Eth...

Страница 4: ...n 9 Operating Specifications 13 Time Server Function 14 Initial Settings 15 Connecting with a Web Browser 16 System Information 17 Authentication 19 Network Configuration 21 SNMP Configuration 23 User...

Страница 5: ...he symbol Device Installation Caution When operating this product as a time server make sure that the network administrator handles the system Managing the IP addresses inappropriately may prevent dev...

Страница 6: ...Always disconnect the power supply before starting wiring work Failure to do so may result in electric shock or malfunction Always use the specified AC adapter provided Using a different adapter may r...

Страница 7: ...J45 Reception monitor Cable support AC adapter connection jack Antenna connection terminal V Initialization button R Antenna cable shield connection terminal SG Antenna connection terminal RX Semicond...

Страница 8: ...cian Up to max 600m GPS antenna Signal converter time server Red Black White Green Shield Red Black White Green Red Black Red Black Network PoE Semiconductor relay output 2 Customer Devices Input term...

Страница 9: ...ed output is stopped after more than 24 hours has passed from the last reception Output resumes when the signal is received again Output rating Applicable voltage 24V DC or less Maximum current 200mA...

Страница 10: ...ide Locations that have an object that reflects or intercepts radio waves near the installation location Near wired window glass window glass with smoke film attached metallic slide shutters or window...

Страница 11: ...considering weather resistance Extension length Up to 600m When extending the cable be sure to use the appropriate methods to waterproof connections such as by applying vinyl tape and self adhesive t...

Страница 12: ...o press and hold the cable release button and insert the cable into the cable connector After inserting the cable release the cable release button and check that the cable cannot easily be pulled out...

Страница 13: ...e combination of devices connected to the powered HUB Compulsory Use a category 5e or higher 4 pair UTP STP cable Using other types of cables may result in malfunction The maximum cable length is 100m...

Страница 14: ...ding on the reception environment it may take 5 to 25 minutes after switching the power on for the lamp to flash every 2 seconds Flashes green every 2 seconds flashes on a 2 second cycle Normal times...

Страница 15: ...nced must support NTP Network Time Protocol or SNTP Simple Network Time Protocol Either version 3 or 4 Set the time server this device IP address as the reference location for time syncing on the devi...

Страница 16: ...ocol is a protocol for monitoring devices on a network and is useful for discovering operation errors in the time server Returning Settings to Default Values After Changing Settings Remove all of the...

Страница 17: ...URL The initial setting is 192 168 0 200 For the initial settings http 192 168 0 200 enter The System Information screen is displayed If an error or other problem occurs and the screen does not open c...

Страница 18: ...17 System Information You can check the system information by clicking Overview in the top left menu...

Страница 19: ...o communication Communication failure with GPS antenna State Unusual Malfunction of GPS antenna Start Communication with GPS antenna is successful starting to receive signal Wait1 Acquiring GPS satell...

Страница 20: ...ation in the top left menu Advance authentication is required for changing the settings Click Access Restricted Page Enter the user name and password and click OK Initial Settings User Name admin Pass...

Страница 21: ...20 If the login is successful the Login Successful screen opens If you are prompted to enter the information again authentication has failed Check the user name and password...

Страница 22: ...n the Network Configuration screen by clicking Network Configuration in the top left menu Host Name Unique device name single byte alphanumerics maximum 15 characters IP Address IP address Subnet Mask...

Страница 23: ...ged select the IP address that was changed open the screen again and confirm the change If ERROR is displayed there is a problem in the input Check again the characters and number of characters that y...

Страница 24: ...u can access using SNMPv1 or SNMPv2 You can obtain information about the operating status of the time server using SNMP When SNMP Trap is set a warning notification is sent to the IP address that you...

Страница 25: ...box cleared Default setting Disabled Receiver IP Address1 Notification destination IP address 1 Default setting 0 0 0 0 Community1 Community name 1 single byte alphabetic characters maximum 12 charact...

Страница 26: ...ows All the items are read only 20438 citizen watch 190 citizen tic 1 product 1 name 2 version 3 date 4 MacAddress 6 GpsAntennaStatus 2 control 3 network 1 setting 1 IpAddress 2 SubnetMask 3 DefaultGa...

Страница 27: ...elapsed since synchronization 8 No synchronization for 4 hours or more network 1 3 6 1 4 1 20438 190 3 Network information setting 1 3 6 1 4 1 20438 190 3 1 IPAddress 1 3 6 1 4 1 20438 190 3 1 1 IpAd...

Страница 28: ...with antenna 6 Antenna status changed trap 1 3 6 1 4 1 20438 190 4 Trap trapNotifications 1 3 6 1 4 1 20438 190 4 0 Trap notifications sntpDown 1 3 6 1 4 1 20438 190 4 0 1 Time server stopped OBJECTS...

Страница 29: ...ximum 8 characters Retype New Password Password single byte alphanumerics maximum 8 characters To change the settings click Save Config Reboot In Progress is displayed and the settings are saved Selec...

Страница 30: ...e same segment 1 3 You cannot change the settings on the webpage Check that there are no errors in the characters and number of characters that you entered See P 21 and P 28 1 4 You cannot synchronize...

Страница 31: ...e color Description Green RX White RX Black GND Red V Shield SG Signal converter time server Case AES resin light gray Input signal Serial signal Output signal 1 Semiconductor relay output signal 2 sy...

Страница 32: ...unplug the AC adapter to disconnect the power supply and then contact the dealer where you purchased this product Please provide the following information Product name model GPS Time Server TSV 400GP...

Страница 33: ...6 5347 FAX 022 796 5348 Nagoya Branch Shimo Iida cho 4 chome 26 2 Kita ku Nagoya City 462 0865 Japan TEL 052 991 8600 FAX 052 991 8603 Osaka Branch Higashi Nakahama 8 chome 3 20 Joto ku Osaka City 536...

Страница 34: ...be carried out if this product malfunctions during the warranty period and if this product was used according to the precautions described in the instruction manual 2 Repairs will generally incur a f...

Страница 35: ...34...

Страница 36: ...35 Website address http tic citizen co jp H27 04 TSV 400GP 4M3 100...

Отзывы: