14

Part 

Installation Instruction

1. Select the Location for Installation

1-1 Indoor Unit

Preface

1-2 Outdoor Unit

To guarantee the unit working normally,please read the manual carefully before installation,
and try to install it strictly according to this manual.
Earth the air conditioner properly.
Check the connecting cables and pipes carefully,make sure they are correct and firm before
connecting the power of the air conditioner.
The maximum length of the connecting pipe between the indoor unit and outdoor unit should
be less than 5 metres. It will affect the efficiency of the air conditioner if the distance longer
than that length.
After installtaion,the consumer must operate the air conditioner correctly according to this
manual, keep a suitable storage for maintenance and move of the air conditioner in the future.

On a rigid wall without vibration.
No obstacle in front of air inlet and outlet vents,the distance between the upper of the unit and
the ceiling should no less than 10cm.
The place where the cold air can be sent to the whole room.
The maximum distance between the indoor unit and outdoor unit is 5 metres, so does the
height difference between them.
Avoid direct sunlight.
Exhaust water can be easily drained.
The air filter can be installed or removed easily (There should be more than 20 cm space down
from the bottom of the unit to the ground).
The distance between the unit and TV or radio should be more than 1 metre (because the unit
can disturb the images of television and make noise).
The place should more than 1 metre away from the fluorescent lamp or other electric bulbs.
(For they may affect the remote controller working normally).

It should be installed at the place that keeping away from strong wind.
It should be installed at the place where there is good ventilation and low dust.
It should be placed to avoid direct sunlight and rain.
It should be installed at the area where the operating noise will not affect other pelple’s work
and rest.
It should be placed on a rigid frame to aviod vibration or noise.
Keep away from the flammble gases.
When the unit is installed in a high place, make sure to fix the feet of the unit.

Attention:

Do not install the air conditioner in the following
places, or it will cause a breakdown.

The places where the machine oils are highly used.
The places with high salt such as coastal areas.
Hotspring areas.
The places full of sulphur gases.
Other places of special atmosphere environment.

Содержание CSRA-09

Страница 1: ...nditioner Instruction Manual Thank you for purchasing of CITIZEN air conditioner To guarantee safety and best efficiency please read this manual carefully and keep a suitable storage for reference App...

Страница 2: ...en the air conditioner is in using season detailed in inner pages Adopt the world famous compressor and micro computer controlling chip the performance is stable and reliable High efficiency compresso...

Страница 3: ...Indoor Unit Remove Controller Wall mounted Plate Instruction Manual Certificate of Quality Guarantee Certificate Remote Controller s Brace Batteries AAA SIZE 1 5V Outdoor Unit Drain Hose Catchment Tr...

Страница 4: ...nstall removed and reinstall the unit yourself Improper installation may cause leakage electric shock or fire Please engage an authorized dealer or specialist for the installation work Please use eart...

Страница 5: ...t on the unit If abnormal conditions burnt smell etc occur please shut the power switch Do not use the unit for any other purpose Do not shut the power switch by drawing the cord Do not splash or dire...

Страница 6: ...eration Contents Setting Operation of Timer Running Mode Air Direction Controlling Maintenance Method Operation Experience Guide Trouble Shooting Part Installation Instruction Select the Location for...

Страница 7: ...d Functions 1 1 Indoor Unit 6 Outlet vent Intake vent Signal receiving window Air filter nets 2 CSRA 09 CSRA 12 Signal receiving window Indicator Iamps Outlet vent Intake vent Air filter nets 2 Indica...

Страница 8: ...tdoor Unit CSRA 18 CSRA 18 Outlet vent Intake vent Outlet vent Intake vent CSRA 09 CSRA 12 Outlet vent Intake vent Signal receiving window Indicator Iamps Air filter nets 2 Auxiliary buckle 4 Emergenc...

Страница 9: ...ared transmit tube Transmit signal to indoor unit Mode key Choose cooling dehumidifying heating Temperature setting key 16 J30 Wind speed key Choose Low Medium High Auto Air direction adjusting key Ti...

Страница 10: ...uter automatically The remote controller transmit mid speed signal main frame will dispose it as low speed automatically The remote controller should be aimed at the receiving window of the main frame...

Страница 11: ...erature buttons set the temperature you need Press SPEED button choose the fan speed you need Press DIRECTION button choose the air direction you want Stop press button Attention When it turns to the...

Страница 12: ...t with soft cloth CAUTION Please regulate up and down air direction by remote controller Don t regulate the up and down air direction guide board with hand when the unit running or the link will be da...

Страница 13: ...ce between indoor and outdoor should be within 5 or it will do harm to your health Try to reduce the invasion of outdoor heat open the doors or windows as few as possible avoid the direct sunlight try...

Страница 14: ...low Repeatedly heat and defrost The compressor is at delay stage To protect the compressor there are several minutes delay for every start It has the function that can prevent the cold air from blowin...

Страница 15: ...etres so does the height difference between them Avoid direct sunlight Exhaust water can be easily drained The air filter can be installed or removed easily There should be more than 20 cm space down...

Страница 16: ...damaged it must be replaced by the manufacturer or its service agent or similar qualified persons in order to avoid hazard Medium power connecting wire Extended wire of socket Indoor unit Tie a thin c...

Страница 17: ...on the installation plate fix the lower part with a hook 3 Installation of Outdoor Unit It should be installed on the rigid place Such as the concrete object If it was installed on the brick wall the...

Страница 18: ...lted rugged Copper pipe Pipe cutter 2 remove burrs Get rid all the burrs of the pipes section Burr 3 install the nut Remove the connecting nut which is installed on the indoor unit and outdoor unit af...

Страница 19: ...he back of the indoor unit if too thin it will cause dew and water dripping 3 3 Drain Hose For the convenience of draining off water please incline the drain hose downward when ar range it diagram 1 D...

Страница 20: ...crewing them e Please add some connecting wires if the connecting wires are not long enough the diameter of the wire must fit the stipulation and the colour must be the same 4 Test Run 4 1 Pipe cleani...

Страница 21: ...normal Does every indicating lamp light normally Does it drain smoothly 2 Outdoor unit Is there abnomal noise or vibration when it is running Do the noise wind and water caused affect the neighbours I...

Страница 22: ...cuit Extra notice will not be given if there are changes of the data please take the nameplate on the machine as the standard Note 1 2 3 21 Data Model Item CSRA 09 Type Cooling Capacity Heating Capati...

Страница 23: ...Serial No eb48603 Version 070808...

Отзывы: