2-3-3. Removing the Auto Cutter Unit
Note:
Before starting work, be sure to turn off the power of the printer and disconnect the power
cord from the power source.
Remove the Auto Cutter Unit from the printer by performing reverse procedure to installation
procedure.
In this case, while detaching the Cutter Unit from the printer by removing the fastening screw,
hold the Cutter Unit by hand as it can fall down.
2-3-4. Caution when replacing parts
If the following part is removed from the Cutter Stand Unit, adjustment is required when
assembling.
1
Static Eliminator Sheet
Positioning is required.
2
Metal parts that regulate the cutter
slit width
Refer to Chapter 3 "Adjustments".
Static Eliminator Sheet Sticking Position:
Stick the Static Eliminator Sheet to the position shown below.
[Rear view of the Cutter Stand Unit]
Static Eliminator Sheet
0.2 to 0.5 mm
Cutter slit
Cutter Stand Plate
Brush
Cut Guide 2