(Batteries supplied with the unit should be loaded in compartment before you use 
the blood pressure monitor.)

LOADING THE BATTERIES

1

  Open the cover of battery compartment.

 

Pressing the upper part of the battery cover, pull the cover toward you to open.

2

  Place batteries in the compartment.

 

Put the batteries paying attention to the 
positive and negative terminal symbols 

 and  . 

* If the Blood pressure monitor is left unused for an extended period of 

time, the batteries should be removed from the compartment.

Battery cover

Battery compartment

4 “AA” batteries

3

  Close the battery cover.

•  When the icon 

 is displayed or nothing appears in the display, replace the old 

batteries with four new ones. All four batteries should be changed at once.

•  Adjust the clock after changing the batteries.
•  The data stored in the memory is not deleted by changing the batteries.
•  Do not use rechargeable batteries.
•  Do not use alkaline (LR6) and manganese (R6P) batteries together.
•  Batteries included are for demonstration purposes only. Battery life may be 

shorter than specified.

•  When disposing of used batteries, comply with governmental regulations or 

environmental public institution’s rules that apply in your country/area.

REMOVING THE BATTERIES

00̲CHU304̲All.indb   Eng-7

2015/06/02   11:00:49

Содержание CHU304

Страница 1: ...Espa ol English INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR REF CHU304 CHU305 1501 English Espa ol Fran ais Py Please read all of the information in the instruction manual before operating...

Страница 2: ...ing record of your blood pressure variations A complete picture can only be obtained from a large number of readings To obtain correct blood pressure measurements 1 Take five or six deep breaths and t...

Страница 3: ...fications under the WHO standards Remarks The graph is not exact but may be used as a guide in understanding non invasive blood pressure measurements The device is only intended for use by adults Defi...

Страница 4: ...ill be taken or who suffers from a frequent irregular heartbeat Consult your physician for advice on whether to use the monitor 9 DO NOT wrap the cuff around an injured arm 10 DO NOT wrap the cuff aro...

Страница 5: ...as this could damage the monitor 8 To clean the cuff wipe it with a moist cloth Avoid hard rubbing as this will cause air leakages Take care also not to get water into the air hose 9 Clean the cuff a...

Страница 6: ...isposal service or the point of sale where you purchased the items Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If you wish to...

Страница 7: ...hose socket START STOP Switch Stand by See page 7 for the Battery compartment See page 11 for the Irregular Heartbeat IHB Indicator Display Systolic blood pressure display Ready to inflate indicator...

Страница 8: ...he compartment Battery cover Battery compartment 4 AA batteries 3 Close the battery cover When the icon is displayed or nothing appears in the display replace the old batteries with four new ones All...

Страница 9: ...ress the START STOP switch to confirm the setting The month is set and the day indicator blinks You can fast forward the numbers in display by pressing and holding the MEMORY switch 4 Press the MEMORY...

Страница 10: ...palm side Metal hoop 1 Unroll the cuff and thread the end through the metal hoop so that the side with the hook and loop fastener is on the outside The position of the artery 3 Adjust the position of...

Страница 11: ...If the previous user had a high pressure setting that high pressure will automatically be used for the current measurement If the pressurization value exceeds 260 mmHg if pressurization feels abnormal...

Страница 12: ...ected during measurement the Irregular Heartbeat IHB Indicator is displayed after measurement is completed There are 2 conditions under which the signal of IHB will be displayed 1 The coefficient of v...

Страница 13: ...ur hand slightly on the table so that your palm is facing up and your fingers are relaxed 4 Do not move your body or talk while taking the measurement 99 measurement results can be stored in Memory Th...

Страница 14: ...e latest data Data number 1 2 3 98 99 The latest data The earliest data HOW TO DELETE THE DATA 1 When any result except average reading of the last three measurements is displaying press and hold the...

Страница 15: ...e ambient temperature or your mental state When you have a physician or nurse measure your blood pressure the pressure value is likely to be 10 to 20 mmHg higher than usual due to anxiety and or stres...

Страница 16: ...measurement Don t move and try again LCD shows Er 1 Fail to detect systolic pressure LCD shows Er 2 Fail to detect diastolic pressure LCD shows Er 3 Pneumatic system blocked or cuff is too tight duri...

Страница 17: ...idity 90 RH Electric shock protection Internal power unit Degree of Protection Type BF applied part Mode of operation Continuous operation Memory 1 99 readings Average of last 3 readings Service Life...

Страница 18: ...oltage uctuations icker emissions IEC 61000 3 3 N A Guidance and manufacturer s declaration electromagnetic immunity The CHU304 CH305 is intended for use in the electromagnetic environment speci ed be...

Страница 19: ...due to xed RF transmitters an electromagnetic site survey should be considered If the measured eld strength in the location in which the CHU304 CH305 is used exceeds the applicable RF compliance leve...

Страница 20: ...CITIZEN is a registered trademark of Citizen Holdings Co Japan Design and Specification are subject to change without notice...

Отзывы: