8
5.5
Clean up
1
Place a bucket under the modulator to catch falling water, and run 1-gallon fresh water
through system each night to clean and freshen equipment. Unplug GFI from power
source. Wipe off output end and any excess foam. Make sure no fluid has dripped or
splashed on the electrical components. Blow-dry with an air hose if necessary.
2
Clean up of the foam is easy. Some water may need to be mopped and removed. Use of
a wet/dry vacuum may be needed.
3
Foam Dome
TM
Fluid is non-toxic, clean, easy to use and can be very fluffy. Fluid will not
damage clothing.
5.6
Troubleshooting
o
If unit does not start:
Check electrical power for properly grounded outlet. Check
GFCI box (see instructions in section 3.2). Check power cord going to GFCI box for
cuts or separation.
o
If the fan is not operating:
Check Fan separately by disconnecting the pump from
the GFCI. Does the fan rotate? If foam has gotten inside the unit, disconnect the
hose and blow out the unit with an air line. If not available, discontinue use until
completely dry.
o
If the fan rotates, but is not very fast:
Power loss will cause this unit to not function
properly. Verify that any extension cords are 12 awg or larger and less than 100 feet
long. Unplug other equipment that is on the same circuit.
o
If you are not getting fluid to the Super Foam Dome
TM
unit:
Check pump
separately by disconnecting from the hose and by disconnecting the fan from the
GFCI and turning on the unit for a short time. If pump does not work, check another
power outlet. If it still does not work, replace unit by calling for assistance.
o
If the unit was foaming, then stops:
o Check the intake hose of the pump in the bottom of the barrel. Certify that there is
sufficient fluid. Keep the barrel clean and occasionally check to be sure dirt is not
getting inside the barrel, as this will clog the pump. Shut off all power, disconnect
the pump from the GFCI and remove the pump from the barrel. Disconnect the
hoses and check for debris or dirt that may be clogging the unit. Connect the
suction hose to the pump and plug in the pump separately to see the output,
catching the output in a bucket. The output should be open and free.
o Check the nylon tubing going to the Super Foam Dome
TM
unit. If it is crimped or
bent in a 90 degree angle, change the tubing.
o Check the connection to the Super Foam Dome
TM
unit. There is a screen that will
capture dirt from entering the nozzle. Disconnect the tubing and clean the screen
at the connection. Reconnect and try again.