CITC Super Foam Dome 100216 Скачать руководство пользователя страница 5

4. 

Safety instructions 

 

WARNING:  

FAILURE TO FOLLOW ALL SAFETY RULES AND INSTRUCTIONS LISTED 

BELOW MAY RESULT IN SERIOUS INJURY TO YOURSELF OR OTHER 
PARTICIPANTS OF THIS EFFECT.

  

 

RISK OF ELECTRICAL SHOCK:  

 

1.  Keep all electrical appliances away from the foam area. 
2.  Do not touch Super Foam Dome

TM

 or GFI switching device when wet. 

3.  This device is to be used on normal distribution systems 120 VAC/60Hz/20A. This 

device is designed to be used with the supplied Ground Fault Interrupter (GFI), which 
has a grounding conductor. To reduce risk of electrical shock, connect only to a 
properly grounded, grounding type receptacle. Never remove the third prong from the 
plug on the GFI, the pump or the Super Foam Dome

TM

 unit (fan). 

4.  Be aware of foam accumulations near the Super Foam Dome

TM

 electrical 

source/power box.  Since the Super Foam Dome

TM

 is a very high output unit capable 

of extreme volumes of foam, place in an area that allows full release of foam from 
nozzle (front outlet) in all directions.  

 

NOTES ON GROUND FAULT INTERRUPTER (GFI): 

1.  This GFI is a safety device; do not use the test and reset buttons as an on/off switch. 
2.  Ground Fault Circuit Interrupters (GFI) do not protect against electrical shock resulting 

from contact with both current-carrying conductors of an electrical circuit. 

3.  Do not connect an extension cord longer than 100 feet to the GFI output to avoid the 

possibility of nuisance tripping. 

4.  Test frequently and before each use to ensure proper operation, by following 

operating instructions in section 3.2. 

5.  DO NOT USE where water may enter GFI case. 
6.  DO NOT MODIFY OR IMMERSE this device. 
7.  DO NOT EXCEED electrical rating. 

 

o

 

SLIP HAZARD:

  

The accumulation of foam on a slick floor can create a dangerous 

environment, which could cause someone to fall. For safety reasons, the makers of the 
Super Foam Dome

TM

 require using this machine or Foam Dome

TM

 Fluid on a non-slip 

surface such as indoor/outdoor carpeting, turf, or asphalt.

 

 

GLASS:

 Do not allow glassware or breakables in foam area.  If glass breaks in foam 

area, evacuate all persons immediately until cleaned up. 

 

SUPERVISION: 

  No pushing, shoving or horseplay allowed. No diving, running or body 

bowling.  Intoxicated individuals should leave foam area.

 

 

EXPOSURE TO FOAM: 

Avoid prolonged eye contact. Wash eyes with water if irritated.  

Always rinse body after having contact with foam just as you would after contact with 
soap, to prevent excess drying of skin.  If irritation or allergic reaction occurs, individual 
should leave foam area immediately and wash irritated area.  Do not wear soaked 
clothing for more than 4 hours without rinsing.

 

Содержание Super Foam Dome 100216

Страница 1: ...SUPER FOAM DOMETM Operating Instructions P N 100216 120 VAC ...

Страница 2: ...product is quite extensive To guarantee perfect and successful work with this machine please take some time to read the manual carefully And finally we believe you will enjoy years of great foam effects if you care for and maintain your SUPER FOAM DOMETM CITC 1420 80th St SW D Everett WA 98203 888 786 CITC www citcfx com ...

Страница 3: ... DomeTM 5 5 1 Selecting the location 5 2 Electrical Power Requirements 5 3 Hooking things up 5 4 Operating the machine 5 5 Cleanup 5 6 Troubleshooting 6 Service and Maintenance 9 6 1 Super Foam DomeTM Pump Information 6 2 Getting the most from your Super Foam DomeTM Pump 7 Technical Data 10 8 Limited Warranty Conditions 11 ...

Страница 4: ...ducts you ordered are supplied 3 Description of the Super Foam DomeTM The Super Foam DomeTM makes massive amounts of foam 500 cubic feet per minute 14m3 min quickly and harmlessly with its high powered quiet fan It will actually fill a 20 x 20 x 6 pit in less than 5 minutes The Super Foam DomeTM uses a clean harmless and biodegradable fluid to make foam which will last 5 to 10 minutes in dry condi...

Страница 5: ...esulting from contact with both current carrying conductors of an electrical circuit 3 Do not connect an extension cord longer than 100 feet to the GFI output to avoid the possibility of nuisance tripping 4 Test frequently and before each use to ensure proper operation by following operating instructions in section 3 2 5 DO NOT USE where water may enter GFI case 6 DO NOT MODIFY OR IMMERSE this dev...

Страница 6: ...g circuits consult a qualified electrician 2 You must have both units connected through the Ground Fault Interrupter GFI in order to use this device 1 Plug GFI into a well grounded 120VAC 20A circuit If you have any doubt about the circuit s safety ground plug in testers are available to test the outlet If in doubt discontinue trying to power this unit until the outlet can be checked by an electri...

Страница 7: ...e is an irritant to eyes Wear eye protection and gloves when mixing If concentrate contacts eyes immediately wash with plenty of water for 15 minutes while lifting eyelids Consult a physician Prolonged contact with skin may cause irritation Wash with water If clothing is wet with material change to clean clothes and wash affected skin Not food quality Do not digest If digested treat as dish soap O...

Страница 8: ... power switch should be OFF The GFI should be plugged into a properly grounded outlet Plug both the Super Foam DomeTM and the pump from the barrel into the GFI Both units need to always come on at the same time o Never turn on the pump without the Super Foam DomeTM fan This will cause fluid to pour from fan area to floor Unplug the pump if you need to test only the fan When done switch GFI off and...

Страница 9: ...xtension cords are 12 awg or larger and less than 100 feet long Unplug other equipment that is on the same circuit o If you are not getting fluid to the Super Foam DomeTM unit Check pump separately by disconnecting from the hose and by disconnecting the fan from the GFCI and turning on the unit for a short time If pump does not work check another power outlet If it still does not work replace unit...

Страница 10: ...ia to grow Rinse and let the fan blow out the modulator after each use Never leave the modulator sock wet or dripping with solution 6 Service and Maintenance 6 1 Super Foam DomeTM Pump Information The Super Foam DomeTM pump has built in thermal overload protection which means the unit will automatically shut off when it overheats Once cooled down it will reset and is ready to pump again Power cord...

Страница 11: ...TM Power Cord 6 1 9 m GFI Switch Box Four outlets with lighted power switch GFI Power Cord 6 1 9m Fluid pump High pressure diaphragm pump 45 psi 3 1 bar 1 4gpm 5 3 lpm Pump Power 120 VAC 60 Hz 0 7 A Pump Power Cord 6ft 1 9 m Type of Fluid Super Foam DomeTM fluid water mix Output 500 cubic feet per minute 14m3 min Fluid Consumption Approx 1 gallon per minute 3 8 l min Hose x 4 1 4cm x 1 2m pump hos...

Страница 12: ...ation is not covered by this warranty Using any fluid other than what is recommended for this machine will void warranty No liability is accepted for injury or for loss damage or expense resulting from any interruption whatsoever in the operation of the product or from any consequential loss arising there from No liability is accepted for normal wear and tear We wish to satisfy YOU our customer an...

Страница 13: ...reight costs to and from CITC when under the limited warranty services are the responsibility of the customer Customer must place appropriate insurance on return of product However if product is returned due to factory defect within the first year CITC will cover the cost of returning the repaired unit to the customer 6 Limited warranty services do not cause an extension of the limited warranty pe...

Отзывы: