background image

3.

  

Description of the FogMax

TM

 

 

The FogMax

TM

 w/DMX is CITC’s industry-proven fogging system.  No other 

comparable machine delivers a thicker, whiter output of 30,000 cfm (850m

3

/minute) of 

digitally controlled fog.  Extremely reliable, the FogMax

TM

 can produce longer on high 

than the stiffest competition.  Accurate temp control makes shut down history.  It now 
has a quieter pump with a 1500 watt heating head, a 1-channel DMX on board, remote 
control cycle-timer and hanging bracket.  The FogMax™ is your best bet for 
professional fog.  Uses water-based CITC SmartFog™ fluid in 15 Minute, 1 Minute, 3 
Minute, 25 Minute, 45 Minute or 60 Minute.  The extra dry fog leaves no mess, no 
residue and can be fully controlled with DMX. 

 

The following sequence produces fog: 
1.  The fog generator is preheated for 5 – 10 minutes. 
2.  The pump is controlled from 0 – 100% output by the Remote Cycle-Timer 

Controller or by DMX.  

3.  At 12 o’clock output, the unit will produce fog continuously without delay  
4.  At 100% output (3 o’clock on Volume Control), the unit will produce a heavy fog 

for 30 minutes or more without delays.  After a short rest period the FogMax™ 
is again warmed up and ready to produce fog.  

 

4.

 

   Safety instructions 

 

WARNING: Read and understand all labels and operating 

instructions before attempting installation. 

 

o

 

Never open the machine without disconnecting power lead first! 

Risk of electrical shock- 

This device is supplied with a grounding conductor. To 

reduce risk of electrical shock, connect only to properly grounded, grounding type 
receptacles. Never remove the third prong from the plug. 

o

 

This machine requires a 120VAC/20A circuit for operation (or a 230VAC/10A circuit for 
the 230VAC machine).  The FogMax

TM

 draws approximately 15 amps at 120 VAC (8 

amps at 230VAC). During FogMax

TM

 operation this circuit should be dedicated to the 

FogMax

TM

.  If you have any doubts about the capacity or grounding of your existing 

circuits, consult a qualified electrician.  

o

 

Be sure area around fogger is dry before applying electrical power. 

o

 

Make sure that your unit is pointed in a direction that leaves a 10ft (3m) open area out 
in front. Place the front of the machine away from direct contact with electrical 
instruments and people.  Close output is very hot and wet.    

o

 

Never operate the pump without fluid passing through the tube. Operating the pump 
without fluid can cause damage that is not covered under warranty. 

o

 

Fluid is very slippery when spilled.  Care in keeping any drips or spills cleaned up is 
necessary. 

o

 

Do not store FogMax

TM

 in freezing conditions. 

 

 

 

Содержание FogMax 100090

Страница 1: ...FOGMAXTM Operating Instructions P N 100090 120 VAC w DMX P N 100095 230 VAC w DMX ...

Страница 2: ...roduct is quite extensive To guarantee perfect and successful work with this machine please take some time to read the manual carefully And finally we believe you will enjoy years of great smoke effects if you care for and maintain your FOGMAXTM CITC 1420 80th St SW D Everett WA 98203 888 786 CITC www citcfx com ...

Страница 3: ...4 5 Operating the FogMaxTM 5 5 1 Selecting the Location 5 2 Electrical Power Requirements 5 3 Hooking things up 5 4 Operating the machine 5 5 DMX Control 5 6 Rest Period 5 7 Shut Down 5 8 Troubleshooting 5 9 Notes on DMX Control 6 Service and Maintenance 7 7 Technical Data 7 8 Limited Warranty Conditions 8 ...

Страница 4: ...ubitainer P N 150460 60 Minute Longest Lasting SmartFog Fluid P N 150450 45 Minute Long Lasting SmartFog Fluid P N 150410 25 Minute Regular SmartFog Fluid P N 150411 15 Minute Fog It SmartFog Fluid P N 150490 3 Minute Low Ground SmartFog Fluid P N 150491 1 Minute Quick SmartFog Fluid C Clamp w Safety Cable P N 250110 C Clamp w eyebolt hanging harness for 5 gallon 19 liter Cubitainer P N 250076 Ple...

Страница 5: ...g 4 Safety instructions WARNING Read and understand all labels and operating instructions before attempting installation o Never open the machine without disconnecting power lead first Risk of electrical shock This device is supplied with a grounding conductor To reduce risk of electrical shock connect only to properly grounded grounding type receptacles Never remove the third prong from the plug ...

Страница 6: ...let marked Remote Control Fill the bottle with CITC s SmartFog Fluid Place the filter end of the tube inside the bottom of the bottle and tighten cap Be sure the vent hole in the cap is not blocked 5 4 Operating the machine with the remote 1 Turn on the power switch on the fogger Verify that the red light in the switch and the red power LED on the remote both illuminate Wait approximately 7 10 min...

Страница 7: ...p primed Note do not run the pump without fluid passing through the tube This can cause damage to the pump and is not covered under warranty 5 9 Notes on DMX operation Each DMX d unit will occupy a unique DMX address on the DMX chain By adjusting the dip switches on the side of the machine near the DMX cable plug ins the user may assign one address to the machine giving you on off and volume contr...

Страница 8: ...cal Data FogMax Technical Data P N 100090 100095 Type of Fog Thick white dry low ground fog Size 22 x 9 x 11 56cm x 23cm x 28cm Weight 26 lbs 12 kg Shipping Box Size 26 x 13 x 16 66 cm x 33 cm x 41 cm Shipping Weight 33 lbs 15 kg DMX Built in 1 channel DMX CITC SmartFog Fluid water based P N 150460 60 Minute Longest Lasting P N 150450 45 Minute Long Lasting P N 150410 25 Minute Regular P N 150490 ...

Страница 9: ...Damage resulting from shipping accidents misuse negligence unauthorized repairs or modification is not covered by this warranty Using any fluid other than what is recommended for this machine will void warranty No liability is accepted for injury or for loss damage or expense resulting from any interruption whatsoever in the operation of the product or from any consequential loss arising there fro...

Страница 10: ...id has been used or if units are sent in without first emptying the equipment of fluid 5 Freight costs to and from CITC when under the limited warranty services are the responsibility of the customer Customer must place appropriate insurance on return of product However if product is returned due to factory defect within the first year CITC will cover the cost of returning the repaired unit to the...

Отзывы: