background image

repair must be made before receiving your RMA#, in case the unit is not covered 
under this limited warranty. 

 

2.  Repairs/replacements will only be made with the approval of the customer. 

 

3.  Exposure to outside elements voids Warranty. Unit cannot be used outdoors or in 

wet weather without complete protection against the elements. Even then, high 
salty or humid conditions will cause instant corrosion of connectors and will void 
Warranty. 

 

4.  The customer loses all rights for limited warranty services if any repairs or 

adjustments are done to the units by unauthorized persons, and/or if spare parts 
are used, which are not approved by CITC.  The right of limited warranty service is 
also lost if a fluid other than appropriate CITC fluid has been used or if units are 
sent in without first emptying the equipment of fluid.  

 

5.  Freight costs to and from CITC, when under the limited warranty services, are the 

responsibility of the customer. Customer must place appropriate insurance on 
return of product. However, if product is returned due to factory defect within the 
first year, CITC will cover the cost of returning the repaired unit to the customer. 

 

6.  Limited warranty services do not cause an extension of the limited warranty period 

or the start of a new limited warranty period.  The warranty of replaced parts ends 
with the limited warranty period of the whole unit. 

 

7.  Further claims, especially for damages, losses etc. outside the unit are excluded. 

 

Send unit to: 

    

CITC 

RMA # XXXXXXX 
1420 80

th

 St. SW  #D 

Everett, WA  98203 

 
 
 
 
 
 
 
 

 

 

 

 

 

 

 
 

Tel

: (888) 786-CITC or (425) 776-4950 

Fax

:  (425) 776-5129 

Website

:  www.citcfx.com 

E-mail

: [email protected]

 

 

 

Find us on Facebook! 

www.facebook.com/CITCFX 

 

 

March 16, 2018 

Содержание FogMax 100090

Страница 1: ...FOGMAXTM Operating Instructions P N 100090 120 VAC w DMX P N 100095 230 VAC w DMX ...

Страница 2: ...roduct is quite extensive To guarantee perfect and successful work with this machine please take some time to read the manual carefully And finally we believe you will enjoy years of great smoke effects if you care for and maintain your FOGMAXTM CITC 1420 80th St SW D Everett WA 98203 888 786 CITC www citcfx com ...

Страница 3: ...4 5 Operating the FogMaxTM 5 5 1 Selecting the Location 5 2 Electrical Power Requirements 5 3 Hooking things up 5 4 Operating the machine 5 5 DMX Control 5 6 Rest Period 5 7 Shut Down 5 8 Troubleshooting 5 9 Notes on DMX Control 6 Service and Maintenance 7 7 Technical Data 7 8 Limited Warranty Conditions 8 ...

Страница 4: ...ubitainer P N 150460 60 Minute Longest Lasting SmartFog Fluid P N 150450 45 Minute Long Lasting SmartFog Fluid P N 150410 25 Minute Regular SmartFog Fluid P N 150411 15 Minute Fog It SmartFog Fluid P N 150490 3 Minute Low Ground SmartFog Fluid P N 150491 1 Minute Quick SmartFog Fluid C Clamp w Safety Cable P N 250110 C Clamp w eyebolt hanging harness for 5 gallon 19 liter Cubitainer P N 250076 Ple...

Страница 5: ...g 4 Safety instructions WARNING Read and understand all labels and operating instructions before attempting installation o Never open the machine without disconnecting power lead first Risk of electrical shock This device is supplied with a grounding conductor To reduce risk of electrical shock connect only to properly grounded grounding type receptacles Never remove the third prong from the plug ...

Страница 6: ...let marked Remote Control Fill the bottle with CITC s SmartFog Fluid Place the filter end of the tube inside the bottom of the bottle and tighten cap Be sure the vent hole in the cap is not blocked 5 4 Operating the machine with the remote 1 Turn on the power switch on the fogger Verify that the red light in the switch and the red power LED on the remote both illuminate Wait approximately 7 10 min...

Страница 7: ...p primed Note do not run the pump without fluid passing through the tube This can cause damage to the pump and is not covered under warranty 5 9 Notes on DMX operation Each DMX d unit will occupy a unique DMX address on the DMX chain By adjusting the dip switches on the side of the machine near the DMX cable plug ins the user may assign one address to the machine giving you on off and volume contr...

Страница 8: ...cal Data FogMax Technical Data P N 100090 100095 Type of Fog Thick white dry low ground fog Size 22 x 9 x 11 56cm x 23cm x 28cm Weight 26 lbs 12 kg Shipping Box Size 26 x 13 x 16 66 cm x 33 cm x 41 cm Shipping Weight 33 lbs 15 kg DMX Built in 1 channel DMX CITC SmartFog Fluid water based P N 150460 60 Minute Longest Lasting P N 150450 45 Minute Long Lasting P N 150410 25 Minute Regular P N 150490 ...

Страница 9: ...Damage resulting from shipping accidents misuse negligence unauthorized repairs or modification is not covered by this warranty Using any fluid other than what is recommended for this machine will void warranty No liability is accepted for injury or for loss damage or expense resulting from any interruption whatsoever in the operation of the product or from any consequential loss arising there fro...

Страница 10: ...id has been used or if units are sent in without first emptying the equipment of fluid 5 Freight costs to and from CITC when under the limited warranty services are the responsibility of the customer Customer must place appropriate insurance on return of product However if product is returned due to factory defect within the first year CITC will cover the cost of returning the repaired unit to the...