12 | cistermiser.co.uk
Have a question? Call our customer support team on 0118 969 1611
9. Usage advice and specification
Fill Valve (supplied with EVO CISTERN only)
Minimum working pressure:
0.1 bar
Maximum working pressure:
10 bar
Independent
1A (6W) at 6VDC
0-40 °C
100-250v AC 50/60Hz 1A MAX
Factory settings
Range (Wave):
Range (Walkaway):
Refill duration after part flush:
Refill duration after full flush:
Part flush duration:
Full flush duration:
Power requirements:
Normal battery life:
Cleaning:
Lens care:
Electronic specification
Control classification:
Maximum load:
Rated temperature range:
Mains power supply:
~10cm
~55cm (~6cm for hand activation)
40 seconds
60 seconds
2¾ seconds
6 seconds
Either 6V from 4 x alkaline AA (LR6) batteries or 6V DC
regulated from mains adaptor (1A fused spur required)
27 000 cycles
Clean with soap and water only
Infrared lens can be polished with a soft cloth