Page 65
125 lb. Dryer Electric Heating Unit
Rated Heater Input
80kW @ 208V/3Ph.
80kW @ 240V/3Ph.
80kW @ 480V/3Ph.
80kW @ 240/415V/3Ph.
80kW @ 575V/3Ph.
Heater Amps,
Motor Amps,
Controls Amps,
Total Amperes
at Rated
Voltage
232 Amps
201 Amps
100 Amps
202/116 Amps
84 Amps
Minimum Size
Supply Wire
Based on 60° C
(140° F)
Insulated
Copper
Conductor
Circut
Minimum
Conduit
Trade Size
Branch
Circuit
Maximum
Fuse Size
60
60
60
50
60
300 MCM
250 MCM
1 AWG
250 MCM/
0AWG
4AWG
2 1/2
2 1/2
1 1/2
2 1/2/2
1 1/4
250
225
100
255
90
HZ.
Ref. No. (A)
Electric
Heater
Elements
Electric
Bonnet
Description
Ref. No. (B)
Contactor
Ref. No. (C)
Fuse Holder
Ref. No. (D)
Fuses, Heater
Ref. No. (E)
Terminal
Block
Ref. No. (F)
Fuse, Motor
and Controls
TU11790, 80kW
240V/50/60/3
TU11806, 80kW
240/415/50/3
TU9351, 80kW
550V/3
TU11789, 80kW
208V/60/3
TU6963 (4 each)
TU6963 (4 each)
TU9170 (1 each)
TU6963 (4 each)
TU11096
(4 each)
TU8201 (1 each)
TU11096
(4 each)
TU8200 (1 each)
TU9141 (2 each)
TU11096
(4 each)
TU8201 (1 each)
TU7223
(12 each)
TU7223
(6 each)
TU7071
(6 each)
TU7224
(12 each)
TU8734
TU8734
TU8734
TU8734
TU819709
(3 each)
TU819907
(3 each)
TU819712
(3 each)
HE11080(2 each)
30kW/240V
HE10810 (2 each)
30kW/240V
HE10610 (2 each)
40kW/208V
HE10610(2 each)
40kW/208V
Содержание HD125
Страница 9: ...Page 9 125 lb General Dimensions Illustration...
Страница 10: ...Page 10 125 lb Steam Heated Dryer Dimensions Illustration...
Страница 14: ...Page 14 Gas Loop Piping and Gas Supply Piping System Illustrations...
Страница 18: ...Page 18 Steam Piping Installation Illustration...
Страница 20: ...Page 20 Dryer Installation with Multiple Exhaust Illustration...
Страница 27: ...Page 27 Two Timer Models Figures 1 2 and 3 Illustrations...
Страница 35: ...Page 35 DIRECTSPARK IGNITIONOPERATION FLOW CHART...
Страница 37: ...Page 37 Burner Air Inlet Adjustment with Illustration BURNERAIRINLET ADJUSTMENT...
Страница 38: ...Page 38 Basket Alignment for 125 lb Dryers Illustrations...
Страница 66: ...Page 66...