background image

Page 62

TU13692—24V Steam Bonnet (6 Coil) (Illustration)

1 TU7393

Top Plate

2 TU3209

#14 x 5/8” Sheet Metal Screw

(Pkg. of 6) (4 each)

3 TU6080

Air Filter (4 required)

4 TU2808

Steam Coil (6 Coil) (2 each)

5 TU4791

1/2” Angle Connector

6 LB74

#14 Speed Nut (4 each)

7 TU8083

Bonnet Weldment

8 CFB7200

Greenfield Cable 72”

9 TU4790

1/2” Straight Connector

10 TU2846

1/4” Lockwasher

(Pkg. of 6) (2 each)

11 TU4934

1/4” - 20 x 7/16” Hex Nut

(Pkg. of 6) (2 each)

12 TU4605

3/4” Elbow

13 TU4608

3/4” x 2” Nipple (3 each)

14 TU4610

3/4” x 5” Nipple

15 TU4600

3/4” Union

16 TU4620

3/4” x 4 1/2” Nipple

17 TU4597

3/4” Tee (2 each)

18 TU5914

3/4” x 3 1/2” Nipple

19 TU13517

Solenoid Valve 24V

20 TU5431

Bushing

21 FB189

1/4” - 20 x 1” Hex Head
Screw (2 each)

22 TU5726

Rear Coil Holder

Содержание C125E

Страница 1: ...R S MANUAL 125 lb Laundry Dryer MAN2125 8 99 THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER CISSELLMANUFACTURINGCOMPANY HEADQUARTERS PHONE 502 587 1292 831SOUTHFIRSTST SALESFAX 502 585 3625 P O BOX3...

Страница 2: ...gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department Installation and service must be performed by a qualified ins...

Страница 3: ...s wrinkles from setting in and reduces the possibility of spontaneous combustion WARNING Be Safe shut main electrical power and gas supply off externally before attempting service WARNING Never use dr...

Страница 4: ...ent ou vous vous trouvez Evacuez la piece le batiment ou la zone Appelez immediatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le f...

Страница 5: ...service remove or install to diagnose troubles to adjust remove or replace defective equipment or a part nor does it include any responsibility for transportation expense which is involved therein The...

Страница 6: ...er 26 Energy Saving Tips 27 Two Timer Models Instructions 28 30 Moisture Control Models Instructions 31 32 Service Savers 33 TroubleshootingCharts 34 36 Direct SparkIgnitionOperation 37 38 GeneralMain...

Страница 7: ...he Ein conectado off arr t Aus desconectado Hot DoNotTouch Hei NichtBeruhren Hautetemperature Nepas toucher Caliente notocar start demarrage Start arranquedeunmovimiento emission of heat in general mi...

Страница 8: ...danslesdeuxsens DrehbewigunginzweiRichtungen movimientorotativoenlosdos sentidos End of Cycle caution attention Achtung atencion precaucion directionofrotation sens de mouvement continu de rotation Dr...

Страница 9: ...amount of exhaust piping and elbows and allow free access to the rear of dryer for future servicing of belts pulleys and motors Installation clearance from all combustable material is 12 305 mm ceili...

Страница 10: ...Page 10 125 lb General Dimensions Illustration...

Страница 11: ...Page 11 125 lb Steam Heated Dryer Dimensions Illustration...

Страница 12: ...665 lbs 507 kg Export Shipping Dimensions 93 L x 53 W x 78 H 232 7 cu ft 2363 mm x 1347 mm x 1982 mm 6 59 m BTU Input Rating 300 000 Btu h 75 600 kcal h nat mixed and mfg gases 300 000Btu h 75 600 kca...

Страница 13: ...gram furnished with dryer Your dryer is completely wired at the factory and it is only necessary for the electrician to connect the power leads to the wire connectors within the service connection box...

Страница 14: ...dtoasingle gas service Other gas using appliances should be connected upstream from the loop WARNING LIQUIFIEDPETROLEUMGASESONLY A Gas Pressure Regulator for Liquified Petroleum Gases is not furnished...

Страница 15: ...Page 15 Gas Loop Piping and Gas Supply Piping System Illustrations...

Страница 16: ...300000 330000 350000 380000 400000 430000 450000 480000 504000 550000 605000 650000 705000 750000 806000 850000 907000 960000 1000000 3 4 3 4 3 4 3 4 3 4 3 4 1 1 1 1 1 4 1 1 4 1 1 2 1 1 2 1 1 2 2 2 2...

Страница 17: ...pressures in excess of 1 2 PSIG 04 bar 5 The dryer must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply pipi...

Страница 18: ...globe valve in steam supply line and allow steam to flow through dryer to flush out any dirt and scale from dryer This will assure proper operation of trap when connected 6 After flushing system insta...

Страница 19: ...Page 19 Steam Piping Installation Illustration...

Страница 20: ...US36 L44FD42 MODELS L28CD30 L28UR30 L36CD30 L36UR30 L36UR36 L36AR36 L44FD42 MODELS L44CD42 L50CD42 No of Dryers Duct Diameter in inches in CM No of Dryers Duct Diameter in inches in CM No of Dryers Du...

Страница 21: ...Page 21 Dryer Installation with Multiple Exhaust Illustration...

Страница 22: ...loss 4 Zero inches clearance to combustible material allowed on sides and at points within 4 inches 102 mm of front on top 5 Heat loss into laundry room from dryer fronts only is about 60 Btu h 16 kca...

Страница 23: ...305 576 3716 HD20 1 20 9 1 450 765 6 153 87 561 HD30SL 30 13 6 600 1020 8 203 116 748 HD30 1 30 13 6 625 1063 8 203 120 774 HD50 1 50 22 7 850 1445 8 203 164 1058 HD75 1 75 34 1000 1700 8 203 192 1240...

Страница 24: ...osure from the top or side walls See Dryer Make Up Air Requirements Chart 2 Enclosure plenum with service door This separates the dryer air from the room comfort air If dryers use room air instead of...

Страница 25: ...aximum of two 90 bends 2 Use 45 and 30 elbows wherever possible 3 Exhaust each dryer separately 4 Do not install wire mesh or other restrictions in the exhaust duct 5 Use clean outs in the exhaust duc...

Страница 26: ...l or create a fire hazard Rubber easily oxidizes causing excessive heat and possible fire Never dry the above items in the dryer 4 Never let children play near or operate the dryer Serious injury will...

Страница 27: ...yer as soon as it stops This saves having to re start your dryer to remove wrinkles NOTE It is best to run a properly sized bag of rags and or old towels through one or two cycles prior to drying in s...

Страница 28: ...Page 28 Two Timer Models Figures 1 2 and 3 Illustrations...

Страница 29: ...g of the clothes load The light shuts off when cooling time is completed figure 1 on page 26 4 Temperature Selector Select temperature per type of load being dried in the dryer figure 2 on page 26 Hig...

Страница 30: ...er completes its time then the cooling timer will be energized and the cooling light will be On When the cooling timer completes its time the cooling light will turn Off and the End of Cycle light wil...

Страница 31: ...Page 31 Moisture Control Illustration...

Страница 32: ...r the drying cycle is completed then the cooling cycle time will automatically operate The cooling light will be on and indicate the cooling of the clothes load The light shuts off when cooling time i...

Страница 33: ...heating time before the cool down part of the cycle 2 Is the lint screen blocked 3 Is the exhaust duct to the outside clean and not blocked A blocked exhaust will cause slow drying and other problems...

Страница 34: ...th cover in place Replace switch Replace contactor Replace V Belt Adjust belt tension Tighten set screw Remove load Check manual for proper leveling procedures Accidental damage to the fan blade can c...

Страница 35: ...t metal screw in the front panel of dryer and inserting the rubber tube of the vacuum gauge into screw opening See Air Switch Adjustment Sheet in Service Manual Replace Air Switch Check manifold press...

Страница 36: ...rmostat Check for inlet and outlet marking on Check Valve and invert if neccessary Remove plug and blow down Strainer or remove and clean thoroughly if heavily clogged Check piping per Steam Installat...

Страница 37: ...y If the module has multiple retries and no flame is detected the gas valve is de energized and the module goes into an interpurge delay After this delay the module will attempt another trial for igni...

Страница 38: ...Page 38 DIRECTSPARK IGNITIONOPERATION FLOW CHART...

Страница 39: ...erfiveyears thebearingsandhousingshouldbecleaned thoroughly Repackeachbearingandthecavityinbackofthebearingone third fullwithChevronGreaseNo SR1 2 Motorshavingwoolpackedsleevebearingsareoiledatthefact...

Страница 40: ...Page 40 Burner Air Inlet Adjustment with Illustration BURNERAIRINLET ADJUSTMENT...

Страница 41: ...Page 41 Basket Alignment for 125 lb Dryers Illustrations...

Страница 42: ...correct tighten bolts 1 in the following order as viewed from rear of dryer top right bottom left top left and bottom right 6 Tighten bolts 5 until flush against back of dryer Tighten lock nut 4 to s...

Страница 43: ...scrapes or comes closest to scraping the sweep sheet C Mark this position and the nearest rib to this position If it is between two ribs both ribs may need to be shimmed D Remove the basket from the...

Страница 44: ...r blade in position shown hold switch mounting bracket firmly and adjust switch actuator D with needle nose pliers at E by twisting actuator right or left whichever is needed so that switch closes whe...

Страница 45: ...rns off to when it turns on again in the opposite direction Turning the dwell adjustment knob counter clockwise increases the dwell time and turning it clockwise decreases the dwell time Recommended d...

Страница 46: ...ockwise as viewed from back end of motor See arrow on motor support Basket rotates clockwise as viewed from front of tumbler To change rotation of both fan and basket reverse power leads L1 andL2 To c...

Страница 47: ...it can be checked by removing the fill overflow plug on the right hand side of the gear reducer facing rear If oil must be added remove the pop off valve at the top of the gear reducer and add as nee...

Страница 48: ...Page 48 125 lb Laundry Dryer Front Exploded View Illustration...

Страница 49: ...ge DSI 60 TU13409 Spark Ignition Mount 3 Trial Gas only TU13627 Spark Ignition Mount 1 Trial Gas only Specify Color 1 TU8013 Cissell Nameplate 2 TU5739 Support Rod 3 TU14157 Access Panel 4 TU5674 Cont...

Страница 50: ...Page 50 125 lb Dryer Double Motor Models Illustration...

Страница 51: ...ee separate page for parts breakdown 26 500300644 Junction Box 27 TU7517 Basket Shaft Cover TU10732 Prompter Housing Assembly 28 TU7131 3 4 Straight Connector 29 SB170 Junction Box Cover 30 TU13803 Ja...

Страница 52: ...r TU7856 Door w Plain Glass Assy Parts 1 5 TU9318 Door w Solid Panel Assy Parts 3 5 1 TU7862 Door Glass 20 1 4 2 TU7169 Door Glass Gasket 3 TU5503 Door Latch Spacer 4 TUA2319H Door Latch with Keeper 5...

Страница 53: ...eplacement Texas Gage ONLY TU8475 Lens Replacement Marshaltown Inst ONLY TU11193 Lens Replacement Weiss consult factory TU13213 Lens Replacement Weiss consult factory 4 TU490 Thermostat Knob Fahrenhei...

Страница 54: ...ons AIRSWITCHASSEMBLY GasOnly TU8206 1 F888 E Ring 2 TU2463 Actuator Arm 3 TU3476 Air Switch Decal 4 TU1771 6 Tinnerman Nut 5 TU8155 Air Switch 6 TU1770 Insulator 7 TU8171 Air Switch Bracket 8 TU7733...

Страница 55: ...Reversing 2 TU13480 Transformer 200 240V 24V w Reset TU13514 Transformer 480 24V w Reset 3 F540 6 x 5 8 Phillips Head Screw 4 TU13516 Contactor 24V 5 TU13526 ContactorAssembly 24V 6 TU14026 Motor Con...

Страница 56: ...dment 5 TUT316 LED 6 TU7733 8 18 x 1 2 Self Drill Scr 7 TU2555 Knob Assembly 8 ET208 6 32 x 1 4 Binding Head Screw 9 TU3805 Hex Nut 10 TU13825 Control Panel 11 TU12932 Timer 0 60 Minutes 12 TU3479 Pan...

Страница 57: ...10 TU12933 Timer 0 15 Min Cooling 11 TU13229 24V Humidity Based Controller 12 TU13345 DPDT Switch 13 TU13620 Timer Control Weldment 14 TU13646 24V Coil Relay 15 TU14251 Front Panel 125 ICC 16 TU2555 K...

Страница 58: ...Cap 8 TM204 Small Klozure 9 TM218 Small Closed End Cap 10 VSB134 3 8 Split Lockwasher Pkg of 6 11 TU3246 3 8 16 x 1 Cap Screw Pkg of 6 12 TM217 Large Bearing Cone Cup 13 TM220 Large Klozure 14 TM221...

Страница 59: ...0946 Pipe Plug 9 TU13613 Bonnet Assembly 10 GA 00764 0 Direct Spark Ignition Electrode 11 TU4605 3 4 Elbow 12 TU4606 3 4 x 4 Nipple 13 TU4934 1 4 20 Hex Nut Pkg 6 14 TU13823 3 4 x 36 Nipple 15 TU3539...

Страница 60: ...7 TU8083 Bonnet Weldment 10 TU2846 1 4 Lockwasher Pkg of 6 11 TU4934 1 4 20 x 7 16 Hex Nut Pkg of 6 12 TU4605 3 4 Elbow 13 TU4608 3 4 x 2 Nipple 14 TU4610 3 4 x 5 Nipple 15 TU4600 3 4 Union 16 TU4620...

Страница 61: ...24V 20 TU5431 Bushing 21 FB189 1 4 20 x 1 Hex Head Screw 2 each 22 TU5726 Rear Coil Holder 1 TU7393 Top Plate 2 TU3209 14 x 5 8 Sheet Metal Screw Pkg of 6 4 each 3 TU6458 Air Filter 4 required 4 TU169...

Страница 62: ...t Weldment 8 CFB7200 Greenfield Cable 72 9 TU4790 1 2 Straight Connector 10 TU2846 1 4 Lockwasher Pkg of 6 2 each 11 TU4934 1 4 20 x 7 16 Hex Nut Pkg of 6 2 each 12 TU4605 3 4 Elbow 13 TU4608 3 4 x 2...

Страница 63: ...Page 63...

Отзывы: