Page 44
Air Switch Adjustment
AIR SWITCH
ADJUSTMENT
1. Shut off current; disconnect leads and remove air switch.
2. Lay air switch assembly on flat surface. Adjust air blade at
“A” (figure 1) so that air blade lays flat and surface “B” is
parallel to the flat surface.
3. Place 3/8” x 5/8” (10 mm x 16 mm) spacer bar or equivalent
“C” (figure 2) under air blade in position shown; hold switch
mounting bracket firmly and adjust switch actuator “D” with
needle nose pliers at “E” by twisting actuator right or left,
whichever is needed, so that switch closes when end of air
blade engages bar “C”.
4. Maximum opening of air switch must be no greater than
3/4” (20 mm) (figure 3). Bend tab “F” in or out to maintain
this dimension.
5. Re-install air switch assembly on rear of dryer.
6. Re-check operation of air blade. Switch must close before
air blade engages face of opening and re-open before stop
“F” engages.
Содержание C125E
Страница 10: ...Page 10 125 lb General Dimensions Illustration...
Страница 11: ...Page 11 125 lb Steam Heated Dryer Dimensions Illustration...
Страница 15: ...Page 15 Gas Loop Piping and Gas Supply Piping System Illustrations...
Страница 19: ...Page 19 Steam Piping Installation Illustration...
Страница 21: ...Page 21 Dryer Installation with Multiple Exhaust Illustration...
Страница 28: ...Page 28 Two Timer Models Figures 1 2 and 3 Illustrations...
Страница 31: ...Page 31 Moisture Control Illustration...
Страница 38: ...Page 38 DIRECTSPARK IGNITIONOPERATION FLOW CHART...
Страница 40: ...Page 40 Burner Air Inlet Adjustment with Illustration BURNERAIRINLET ADJUSTMENT...
Страница 41: ...Page 41 Basket Alignment for 125 lb Dryers Illustrations...
Страница 48: ...Page 48 125 lb Laundry Dryer Front Exploded View Illustration...
Страница 50: ...Page 50 125 lb Dryer Double Motor Models Illustration...
Страница 63: ...Page 63...