Troubleshooting Chart
Blow out.
Adjust gas pressure per Rating Plate.
Send to factory for correct orifices.
Clean exhaust.
Check Ground.
Replace orifices. Check factory for correct size.
Replace orifices. Check factory for correct size.
Make-up air must be 4 to 6 times the exhaust area of the
dryer.
Remove lint.
Must be full OPEN or replace.
Adjust gas pressure as specified on Rating Plate.
Check Service section for recommended sizes. Remove
obstructions or lint build up from duct work. NEVER use
smaller size exhaust duct. ALWAYS use larger size.
Replace thermostat.
Replace timer.
Check all valves in steam supply and return. Make sure
they are OPEN.
Remove and clean. Replace if defective.
On dryers using solenoid temperature control, thermostat
controls operation of Solenoid Valve by advancing
thermostat.
On dryers using solenoid temperature control, thermostat
controls operation of Solenoid Valve. If defective, replace
thermostat.
Check for inlet and outlet marking on Check Valve and
invert if neccessary.
Remove plug and blow down Strainer or remove and clean
thoroughly if heavily clogged.
Check piping per Steam Installation Instructions.
Check trap for size and capacity. If dirty and sluggish,
clean thoroughly or replace. Check return line for high
back pressure, or another trap charging against the trap
functioning improperly.
Main Burners burning
improperly.
Main Burner cycles ON
and OFF.
Low or high gas flame.
Dryer too hot.
Dryer does not stop at end
of time period (6).
Dryer runs no steam to
coils.
Water in Steam Line.
TROUBLE
CAUSE
REMEDY
Dirt in burner.
High gas pressure.
Orifice too large.
Restricted or blocked
exhaust.
Defective Ground.
Incorrect Main
Burner orifices.
Incorrect Main
Burner orifice.
Inadequate make-up
air.
Lint accumulated.
Exhaust duct
dampers.
High gas pressure.
Partially restricted or
inadequately sized
exhaust system.
Defective thermostat.
Defective timer.
Valve CLOSED.
Steam Trap blocked.
Solenoid Valve.
Thermostat.
Check Valve in-
stalled incorrectly.
Strainer clogged.
Steam Piping in-
stalled incorrectly.
Trap not functioning.
Содержание C125E
Страница 10: ...Page 10 125 lb General Dimensions Illustration...
Страница 11: ...Page 11 125 lb Steam Heated Dryer Dimensions Illustration...
Страница 15: ...Page 15 Gas Loop Piping and Gas Supply Piping System Illustrations...
Страница 19: ...Page 19 Steam Piping Installation Illustration...
Страница 21: ...Page 21 Dryer Installation with Multiple Exhaust Illustration...
Страница 28: ...Page 28 Two Timer Models Figures 1 2 and 3 Illustrations...
Страница 31: ...Page 31 Moisture Control Illustration...
Страница 38: ...Page 38 DIRECTSPARK IGNITIONOPERATION FLOW CHART...
Страница 40: ...Page 40 Burner Air Inlet Adjustment with Illustration BURNERAIRINLET ADJUSTMENT...
Страница 41: ...Page 41 Basket Alignment for 125 lb Dryers Illustrations...
Страница 48: ...Page 48 125 lb Laundry Dryer Front Exploded View Illustration...
Страница 50: ...Page 50 125 lb Dryer Double Motor Models Illustration...
Страница 63: ...Page 63...