Replacing Memory Risers
The memory risers connect to the motherboard and each riser provides eight DIMM slots. The memory
riser is hot-swappable when you use the Attention button, as described in the following procedure.
Figure 3-16
Memory Riser LEDs (Top View)
The qualified and supported part numbers for this component are subject to change over time. For the most
up-to-date list of replaceable components, see the following URL and then scroll to
Technical Specifications
:
http://www.cisco.com/en/US/products/ps10493/products_data_sheets_list.html
To replace or install a hot-swappable memory riser, follow these steps:
Step 1
Remove the memory riser that you are replacing: See
Figure 3-17
:
a.
Slide the server out the front of the rack far enough so that you can remove the top cover.
b.
Remove the top cover as described in
“Removing and Replacing the Server Top Cover” section on
page 3-7
.
c.
Press the attention button (ATTN BUTTON) on the top of the memory riser (see
Figure 3-16
).
d.
Wait until the attention LED (ATTN) and the power LED turn off.
e.
Simultaneously press both green release buttons on the top of the memory riser to release the riser
retaining latches. The latches open up to a 45-degree angle when they are released.
f.
Grasp the open retaining latches and lift the memory riser straight up and out of the motherboard
connector.
g.
If you are installing or replacing DIMMs on the memory riser, use the instructions in
Replacing
DIMMs, page 3-28
.
Step 2
Install (hot-add) a new memory riser:
a.
Ensure that the riser release latches are in the open position.
a.
Align the riser with the empty motherboard connector.
b.
Push the riser into the connector until it is seated and the open release levers engage.
1
Attention button (used for hot-swapping and
hot-adding)
2
Attention LED (indicates when hot-swapping
is safe)
3
Power LED (indicates whether the riser has
power)
4
Mirror activity LED (indicates whether
memory mirroring is enabled)
5
DIMM fault LEDs 1 through 8
(indicate which DIMM has failed)
198939
1
5
2
3
4
Содержание UCS C460
Страница 6: ...Contents vi Cisco UCS C460 Server Installation and Service Guide OL 22326 01 ...
Страница 12: ...xii Cisco UCS C460 Server Installation and Service Guide OL 22326 01 Preface ...
Страница 14: ...xiv Cisco UCS C460 Server Installation and Service Guide OL 22326 01 Preface ...
Страница 106: ...D 2 Cisco UCS C460 Server Installation and Service Guide OL 22326 01 Appendix D Installation for Cisco UCS Integration ...