Cisco UCS C260 M2 High-Performance Rack-Mount Server
CONFIGURING the SERVER
21
Approved Configurations
(1) Slot Usage Guidelines
■
For the best performance, populate the PCIe slots in the order shown in
Table 10
for each
type of add-on card. For each card type, populate the primary slot first, followed by the
secondary slot, then any alternate slots. See
Figure 4
for the slot locations.
UCS Storage Accelerators
UCSC-F-FIO-3000M
Cisco UCS 3.0 TB MLC Fusion ioDrive2 for C-Series Servers
Full
UCSC-F-FIO-1205M
Cisco UCS 1205 GB MLC Fusion ioDrive2 for C-Series Servers
Half
UCSC-F-FIO-785M
Cisco UCS 785 GB MLC Fusion ioDrive2 for C-Series Servers
Half
UCSC-F-FIO-365M
Cisco UCS 365GB MLC Fusion ioDrive2 for C-Series Servers
Half
Table 10 Recommended PCIe Slot Population
PCIe Card Type
Primary Slot
Secondary Slot
Alternate Slots
RAID Controller
3
5
—
Low-profile NIC
6
3
1, 2, 5, or 7
Cisco UCS 1225
Virtual Interface Card
7
1
10GbE PCIe LOM (dual port SFP+)
4
1
Notes . . .
1. Slot 4 is reserved for the 10 GbE PCIe LOM card. No other PCIe card may be installed there.
—
—
UCS Storage Accelerators
UCSC-F-FIO-3000M
2
2. The UCSC-F-FIO-3000M is a full-height card and must be installed only in slots 1 or 7
—
—
1, 7
UCSC-F-FIO-1205M
3
3. Not supported in slot 4
—
—
1, 2, 3, 5, 6, 7
UCSC-F-FIO-785M
3
—
—
1, 2, 3, 5, 6, 7
UCSC-F-FIO-365M
3
—
—
1, 2, 3, 5, 6, 7
Table 9 Available PCIe Option Cards
(continued)
Product ID (PID)
PID Description
Card
Height